Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Permit Number - TC-RES-0524-02709

Inspection Description - COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
07/18/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required 7.18.25
No plans on site
Stud shoes or sister studs required at per notched areas in south bathroom
DWV not under test
DWV not secured properly
Bang plate at dryer vent
Fire blocking required at south ceiling area
Showers not under test
Seal penetrations at kitchen vent
Add securing straps every 10ft at kitchen vent
Can note use drywall screws at S connector securing kitchen duct
Secure return air at south hall
Seal penetrations throughout
STOPPED INSPECTION MORE ITEMS MAY BE PRESENT
07/25/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required 2.25.25
Previous corrections made however circuit count does not match plans