Permit: TC-RES-0426-01933
Permit Details
Status:
Inspections Complete
Type:
Residential Building - One or Two Family
Address:
3356 E 5TH ST
Address NEW:
3356 E 5TH ST
Apply Date:
04/16/2026
Applicant:
alex enoch
Description:
REV1: relocated existing gas meter DETACHED SINGLE BAY GARAGE
Permit Reviews
Permit Number - TC-RES-0426-01933
Permit Status: Inspections complete
Permit Description: REV1: relocated existing gas meter
DETACHED SINGLE BAY GARAGE
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/15/2026 | RESIDENTIAL NEW DWELLING REVISION v.1 | N/A | REQUIRES RESUBMIT |
| 05/07/2026 | ADMINISTRATIVE v.2 | N/A | APPROVED |
| 06/24/2026 | RESIDENTIAL NEW DWELLING REVISION v.2 | 06/30/2026 | APPROVED |
| 04/20/2026 | HAST - RESIDENTIAL ADD/ALT FAST TRACK v.1 | 05/05/2026 | APPROVED |
| 05/07/2026 | ADMINISTRATIVE v.1 | 05/07/2026 | REQUIRES RESUBMIT |
Conditions
Permit Number - TC-RES-0426-01933
Permit Status: Inspections complete
Permit Description: REV1: relocated existing gas meter
DETACHED SINGLE BAY GARAGE
| Date | Description | Comments |
|---|---|---|
| 05/07/2026 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-RES-0426-01933
Permite Description: REV1: relocated existing gas meter
DETACHED SINGLE BAY GARAGE
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/26/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Re-inspection required | 06/26/2025 Loose anchor bolts throughout, add anchor bolts at marked locations within 12" of edge and no more than 3.5" for splices. Two anchor bolts required for sill plate with larger than 12". Top plate splices on west and east within 24"requires 10x nails on each side, repair rear column that is misaligned with concrete pad, add straps or h2.5 for beam to column connection, add A34 clip of on rear rafter sides to ledger. |
| 06/30/2026 | BULD - Electrical Clearance | N/A | Not Applicable |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-RES-0426-01933
Permit Description: REV1: relocated existing gas meter
DETACHED SINGLE BAY GARAGE
Total Completed Inspections - 10
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/26/2026 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
| 06/26/2026 | COT - RSBU - Roof Nailing | Passed | ||
| 06/30/2026 | COT - BULD - SWG Clearance | Passed | 06/30/2026 Clearance for SWG. |
|
| 06/30/2026 | COT - RSEL - Electrical Underground | Passed | 06/30/2026 1" sch 80 conduit from panel to garage sub panel, okay to backfill. |
|
| 06/30/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | ||
| 07/08/2026 | COT - RSBU - Firewall/Fire Barrier/Firestop | Passed | ||
| 07/08/2026 | COT - RSBU - Interior Shear Bracing | Passed | ||
| 07/22/2026 | COT - RSPL - Gas Final | Passed | Passed | |
| 07/22/2026 | COT - RSEL - Electrical Final | Passed | Passed | |
| 07/22/2026 | RSBU - Building Final | Passed | Passed |