Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections Complete
Type:
Residential Building - One or Two Family
Address:
3356 E 5TH ST
Address NEW:
3356 E 5TH ST
Apply Date:
04/16/2026
Applicant:
alex enoch
Description:
REV1: relocated existing gas meter DETACHED SINGLE BAY GARAGE

Permit Reviews

Permit Number - TC-RES-0426-01933
Permit Status: Inspections complete
Permit Description: REV1: relocated existing gas meter DETACHED SINGLE BAY GARAGE
Start Date Submittal Complete Date Status  
06/15/2026 RESIDENTIAL NEW DWELLING REVISION v.1 N/A REQUIRES RESUBMIT Review Details
05/07/2026 ADMINISTRATIVE v.2 N/A APPROVED Review Details
06/24/2026 RESIDENTIAL NEW DWELLING REVISION v.2 06/30/2026 APPROVED Review Details
04/20/2026 HAST - RESIDENTIAL ADD/ALT FAST TRACK v.1 05/05/2026 APPROVED Review Details
05/07/2026 ADMINISTRATIVE v.1 05/07/2026 REQUIRES RESUBMIT Review Details

Conditions

Permit Number - TC-RES-0426-01933
Permit Status: Inspections complete
Permit Description: REV1: relocated existing gas meter DETACHED SINGLE BAY GARAGE
Date Description Comments
05/07/2026 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Outstanding Inspections

Permit Status: Inspections Complete
Permit Number: TC-RES-0426-01933
Permite Description: REV1: relocated existing gas meter DETACHED SINGLE BAY GARAGE
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
06/26/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Re-inspection required 06/26/2025
Loose anchor bolts throughout, add anchor bolts at marked locations within 12" of edge and no more than 3.5" for splices. Two anchor bolts required for sill plate with larger than 12". Top plate splices on west and east within 24"requires 10x nails on each side, repair rear column that is misaligned with concrete pad, add straps or h2.5 for beam to column connection, add A34 clip of on rear rafter sides to ledger.
06/30/2026 BULD - Electrical Clearance N/A Not Applicable

Completed Inspections

Permit Status: Inspections Complete
Permit Number: TC-RES-0426-01933
Permit Description: REV1: relocated existing gas meter DETACHED SINGLE BAY GARAGE
Total Completed Inspections - 10
Date Description Inspector Results Comments
05/26/2026 COT - RSBU - Excavation/Rebar/Zoning Passed
06/26/2026 COT - RSBU - Roof Nailing Passed
06/30/2026 COT - BULD - SWG Clearance Passed 06/30/2026
Clearance for SWG.
06/30/2026 COT - RSEL - Electrical Underground Passed 06/30/2026
1" sch 80 conduit from panel to garage sub panel, okay to backfill.
06/30/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed
07/08/2026 COT - RSBU - Firewall/Fire Barrier/Firestop Passed
07/08/2026 COT - RSBU - Interior Shear Bracing Passed
07/22/2026 COT - RSPL - Gas Final Passed Passed
07/22/2026 COT - RSEL - Electrical Final Passed Passed
07/22/2026 RSBU - Building Final Passed Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
CONS-REV SITE V1_V2.PDF DOCUMENTS VIEW
LETTER_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
CONS-PLAN SET V1_V1.PDF DOCUMENTS VIEW