Inspection History Details
Inspection Status: Passed
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/26/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 06/26/2026 Corrections add to same day inspection. |
|
| 06/26/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 06/26/2025 Loose anchor bolts throughout, add anchor bolts at marked locations within 12" of edge and no more than 3.5" for splices. Two anchor bolts required for sill plate with larger than 12". Top plate splices on west and east within 24"requires 10x nails on each side, repair rear column that is misaligned with concrete pad, add straps or h2.5 for beam to column connection, add A34 clip of on rear rafter sides to ledger. |