Permit: TC-RES-0426-01933

Parcel: 12515040A


Addresses:

3356 E 5TH ST

Inspection Status: Passed

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
06/26/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 06/26/2026
Corrections add to same day inspection.
06/26/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 06/26/2025
Loose anchor bolts throughout, add anchor bolts at marked locations within 12" of edge and no more than 3.5" for splices. Two anchor bolts required for sill plate with larger than 12". Top plate splices on west and east within 24"requires 10x nails on each side, repair rear column that is misaligned with concrete pad, add straps or h2.5 for beam to column connection, add A34 clip of on rear rafter sides to ledger.