Permit: TC-RES-0425-01941
Permit Details
Status:
Complete
Type:
Residential Building - One or Two Family
Address:
1917 E 4TH ST
Address NEW:
1917 E 4TH ST
Apply Date:
04/14/2025
Applicant:
TFS Solar
Description:
Roof mount 9.14 kW DC photovoltaic solar system; 21 modules; 13.5 kWh Storage, 1 Tesla Powerwall-3 battery with integrated PV inverter with 4 strings. 200A bus with 200A MCB, interconnection via PCS, Tesla Backup Switch for whole home backup.
Permit Reviews
Permit Number - TC-RES-0425-01941
Permit Status: Complete
Permit Description: Roof mount 9.14 kW DC photovoltaic solar system; 21 modules; 13.5 kWh Storage, 1 Tesla Powerwall-3 battery with integrated PV inverter with 4 strings. 200A bus with 200A MCB, interconnection via PCS, Tesla Backup Switch for whole home backup.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/15/2025 | RESIDENTIAL SOLAR v.1 | 05/29/2025 | APPROVED |
Completed Inspections
Permit Status: Complete
Permit Number: TC-RES-0425-01941
Permit Description: Roof mount 9.14 kW DC photovoltaic solar system; 21 modules; 13.5 kWh Storage, 1 Tesla Powerwall-3 battery with integrated PV inverter with 4 strings. 200A bus with 200A MCB, interconnection via PCS, Tesla Backup Switch for whole home backup.
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/03/2025 | BULD - Electrical Clearance | Passed | 6/17/25 TEP CLEARANCE: DGL, Tesla backup switch. Called TEP @ 10:04. Partial pass pending solar 7.3.25 PV system installed per plans. Proper conductors throughout. Grounding/bonding verified. Neutrals marked. Lugs torqued to spec. Address label on site. Labels verified at panel faces and conduits. Schedule verified. DGC/DGL/BAT CLEARANCE TO TEP |
|
| 07/03/2025 | RSBU - Building Final | Passed | 7.3.25 PV system installed per plans. Proper conductors throughout. Grounding/bonding verified. Neutrals marked. Lugs torqued to spec. Address label on site. Labels verified at panel faces and conduits. Schedule verified. DGC/DGL/BAT CLEARANCE TO TEP |
|
| 07/03/2025 | COT - RSOL - Electrical Final Solar Project | Passed | 6/17/25 TEP CLEARANCE: DGL, Tesla backup switch. Called TEP @ 10:04. Partial pass pending solar 7.3.25 PV system installed per plans. Proper conductors throughout. Grounding/bonding verified. Neutrals marked. Lugs torqued to spec. Address label on site. Labels verified at panel faces and conduits. Schedule verified. DGC/DGL/BAT CLEARANCE TO TEP |