Permit: TC-RES-0425-01884
Permit Details
Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
3926 E LOUIS LN UNIT 2
Address NEW:
3926 E LOUIS LN UNIT 2
Apply Date:
04/10/2025
Applicant:
Description:
ADU Previous Owner Built without permit
Permit Reviews
Permit Number - TC-RES-0425-01884
Permit Status: Inspections
Permit Description: ADU Previous Owner Built without permit
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 12/02/2025 | RESIDENTIAL NEW DWELLING v.3 | 12/11/2025 | REQUIRES RESUBMIT |
| 04/24/2025 | RESIDENTIAL NEW DWELLING v.1 | 05/29/2025 | REQUIRES RESUBMIT |
| 08/13/2025 | RESIDENTIAL NEW DWELLING v.2 | 09/16/2025 | REQUIRES RESUBMIT |
| 12/23/2025 | RESIDENTIAL NEW DWELLING v.4 | 01/05/2026 | APPROVED |
Conditions
Permit Number - TC-RES-0425-01884
Permit Status: Inspections
Permit Description: ADU Previous Owner Built without permit
| Date | Description | Comments |
|---|---|---|
| 04/24/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-RES-0425-01884
Permite Description: ADU Previous Owner Built without permit
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/09/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | 6/9/26: 2-circuits required at kitchen, AFCI circuits required throughout, receptacle spacing not per approved throughout, dryer duct must be 4" smooth material, revision required for HVAC plan, water heater disconnect box mounted to high ( please provide ladder and install lockable shackle at breaker), insulate water lines on exterior of home and protect insulation, refrigeration lines must be properly protected, condensate drain at mini split must be proper terminated, water heater pressure relief valve must be properly terminated with approved piping, panel schedule required. Letter from contractor required prior to final stating that all work performed meets of exceeds 2018 IRC. This should include (electrical, mechanical, plumbing, framing, structural) |