Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Not Ready

Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Permit Number - TC-RES-0425-01884

Inspection Description - COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Inspection Status - Not Ready

Date Description Inspector Results Comments
03/05/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Not Ready Provide record history of all inspections prior to intermediate. Laundry room area stand pipe has to be a minimum of 18". Plans call for 2" line. S trap has been created. Missing exhaust fans. Add nail plates to all lines that are less than an 1 1/4" from the face of the studs. Fire foam all top penetrations. Secure electrical lines from boxes. Missing smoke detectors throughout. Stopped inspection. Other items may vary. 3/5/2026