Inspection Status: Not Ready
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
| Date |
Description |
Inspector |
Results |
Comments |
| 03/05/2026 |
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. |
|
Not Ready |
Provide record history of all inspections prior to intermediate. Laundry room area stand pipe has to be a minimum of 18". Plans call for 2" line. S trap has been created. Missing exhaust fans. Add nail plates to all lines that are less than an 1 1/4" from the face of the studs. Fire foam all top penetrations. Secure electrical lines from boxes. Missing smoke detectors throughout. Stopped inspection. Other items may vary. 3/5/2026 |