Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections
Type:
Residential Building - One or Two Family
Address NEW:
719 S 4TH AV UNIT 1
Apply Date:
04/02/2025
Applicant:
Annheliza Jordaan
Description:
INTERIOR REMODEL OF EXISTING RESIDENCE AT UNIT 1

Permit Reviews

Permit Number - TC-RES-0425-01712
Permit Status: Inspections
Permit Description: INTERIOR REMODEL OF EXISTING RESIDENCE AT UNIT 1
Start Date Submittal Complete Date Status  
05/13/2025 RESIDENTIAL NEW DWELLING v.2 06/10/2025 REQUIRES RESUBMIT Review Details
06/12/2025 RESTAMP - RESIDENTIAL v.1 06/17/2025 APPROVED Review Details
06/12/2025 RESIDENTIAL NEW DWELLING v.3 06/12/2025 APPROVED Review Details
04/08/2025 RESIDENTIAL NEW DWELLING v.1 05/07/2025 REQUIRES RESUBMIT Review Details

Outstanding Activity Conditions

Permit Number - TC-RES-0425-01712
Permit Status: Inspections
Permit Description: INTERIOR REMODEL OF EXISTING RESIDENCE AT UNIT 1
Total Outstanding Activity Conditions - 1
Date Name
05/01/2025 SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED.

Conditions

Permit Number - TC-RES-0425-01712
Permit Status: Inspections
Permit Description: INTERIOR REMODEL OF EXISTING RESIDENCE AT UNIT 1
Date Description Comments
04/08/2025 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-RES-0425-01712
Permite Description: INTERIOR REMODEL OF EXISTING RESIDENCE AT UNIT 1
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
08/18/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Re-inspection required 8/18/26: NM Cable shall be secured within 12" of box (throughout), receptacle spacing shall be no more than 6' from openings and not more than 12' thereafter, all metallic boxes shall be grounded, all penetrations through top plate and vapor barrier shall be sealed, nail plates required where electrical lines and plumbing lines come within 1 1/4" from face of studs, plumbing lines lines require 4x8" nail plates at top and bottom plates, DWV must be properly supported (2" abs require strap mid way vertical lines), gas piping must be properly supported at drop over by entry, framing changes shall be submitted to the city for revision, ensure main panel will have proper working clearances, shower lines will be tested at a later date.

Completed Inspections

Permit Status: Inspections
Permit Number: TC-RES-0425-01712
Permit Description: INTERIOR REMODEL OF EXISTING RESIDENCE AT UNIT 1
Total Completed Inspections - 3

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
ARMORY PARK_MECHANICAL_V1.PDF DOCUMENTS VIEW
CALC-124258 719 SOUTH 4TH AVENUE REMODEL-PHASE 1_V1.PDF DOCUMENTS VIEW
CONS-250427 ARMORY_INSIDE_3RD SUBMISSION_V2.PDF DOCUMENTS VIEW