Permit: TC-RES-0425-01712
Permit Details
Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
719 S 4TH AV UNIT 1
Address NEW:
719 S 4TH AV UNIT 1
Apply Date:
04/02/2025
Applicant:
Annheliza Jordaan
Description:
INTERIOR REMODEL OF EXISTING RESIDENCE AT UNIT 1
Permit Reviews
Permit Number - TC-RES-0425-01712
Permit Status: Inspections
Permit Description: INTERIOR REMODEL OF EXISTING RESIDENCE AT UNIT 1
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/13/2025 | RESIDENTIAL NEW DWELLING v.2 | 06/10/2025 | REQUIRES RESUBMIT |
| 06/12/2025 | RESTAMP - RESIDENTIAL v.1 | 06/17/2025 | APPROVED |
| 06/12/2025 | RESIDENTIAL NEW DWELLING v.3 | 06/12/2025 | APPROVED |
| 04/08/2025 | RESIDENTIAL NEW DWELLING v.1 | 05/07/2025 | REQUIRES RESUBMIT |
Outstanding Activity Conditions
Permit Number - TC-RES-0425-01712
Permit Status: Inspections
Permit Description: INTERIOR REMODEL OF EXISTING RESIDENCE AT UNIT 1
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 05/01/2025 | SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED. |
Conditions
Permit Number - TC-RES-0425-01712
Permit Status: Inspections
Permit Description: INTERIOR REMODEL OF EXISTING RESIDENCE AT UNIT 1
| Date | Description | Comments |
|---|---|---|
| 04/08/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-RES-0425-01712
Permite Description: INTERIOR REMODEL OF EXISTING RESIDENCE AT UNIT 1
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/18/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | 8/18/26: NM Cable shall be secured within 12" of box (throughout), receptacle spacing shall be no more than 6' from openings and not more than 12' thereafter, all metallic boxes shall be grounded, all penetrations through top plate and vapor barrier shall be sealed, nail plates required where electrical lines and plumbing lines come within 1 1/4" from face of studs, plumbing lines lines require 4x8" nail plates at top and bottom plates, DWV must be properly supported (2" abs require strap mid way vertical lines), gas piping must be properly supported at drop over by entry, framing changes shall be submitted to the city for revision, ensure main panel will have proper working clearances, shower lines will be tested at a later date. |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-RES-0425-01712
Permit Description: INTERIOR REMODEL OF EXISTING RESIDENCE AT UNIT 1
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/22/2025 | COT - RSPL - Rough Soil | Passed | Ok to cover progress areas. | |
| 09/02/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | ||
| 09/02/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | Corrections made |