Permit: TC-RES-0326-01527
Permit Details
Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
650 S CAMINO SECO
Address NEW:
650 S CAMINO SECO
Apply Date:
03/26/2026
Applicant:
efren diaz
Description:
Replace Kitchen Beam and Utilities to Island
Permit Reviews
Permit Number - TC-RES-0326-01527
Permit Status: Inspections
Permit Description: Replace Kitchen Beam and Utilities to Island
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/20/2026 | RESIDENTIAL ADD/ALT v.2 | 04/28/2026 | REQUIRES RESUBMIT |
| 04/02/2026 | RESIDENTIAL ADD/ALT v.1 | N/A | REQUIRES RESUBMIT |
| 06/16/2026 | RESIDENTIAL ADD/ALT v.4 | 06/25/2026 | APPROVED |
| 05/15/2026 | RESIDENTIAL ADD/ALT v.3 | N/A | REQUIRES RESUBMIT |
| 06/25/2026 | ADMINISTRATIVE v.1 | N/A | REQUIRES RESUBMIT |
Conditions
Permit Number - TC-RES-0326-01527
Permit Status: Inspections
Permit Description: Replace Kitchen Beam and Utilities to Island
| Date | Description | Comments |
|---|---|---|
| 04/02/2026 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. | |
| 06/23/2026 | Parcel is located within a regulatory floodplain. Engineering review required prior to issuance, floodplain use permit TE-FPU-0526-00197 must be paid prior to issuance. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-RES-0326-01527
Permite Description: Replace Kitchen Beam and Utilities to Island
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/03/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | 8.3.26 1. Missing 2 small appliance circuit in the kitchen, must be on a 20A breaker. 2. Expose ceiling to inspect electrical above. 3. Remove island receptacles not code compliant. 4. Underground electrical conductors for island must be rated for wet location, do not pull Romex. 5. Expose exhaust duct for kitchen hood, must be rigid metal 6. Install water hammer arrestor for Dishwasher 7. Install water hammer arrestor for Ice Maker 8. Bang plates needed at studs to protect wires. 9. Add dedicated refrigerator receptacle. 10. Seal or remove old copper vent for kitchen sink. 11. Dishwasher and garbage disposal needs to be on GFCI. 12. Sill plate must be pressure treated. 13. Update plans to reflect all work being done to include hvac ductwork and diffusers. 14. Secure hi loop for dishwasher drain. 15. Ensure p-trap is plumb. |
| 09/04/2026 | RSBU - Building Final | N/A | Canceled |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-RES-0326-01527
Permit Description: Replace Kitchen Beam and Utilities to Island
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/20/2026 | COT - RSBU - Excavation/Rebar/Zoning | Passed |