Permit: TC-RES-0326-01042
Permit Details
Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
3033 E 3RD ST UNIT 1
Address NEW:
3033 E 3RD ST UNIT 1
Apply Date:
03/01/2026
Applicant:
Megan Waldie
Description:
Renovate 2nd Floor Bedrooms, Bathroom and Relocate Stairway
Permit Reviews
Permit Number - TC-RES-0326-01042
Permit Status: Inspections
Permit Description: Renovate 2nd Floor Bedrooms, Bathroom and Relocate Stairway
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/04/2026 | RESIDENTIAL ADD/ALT v.1 | 03/23/2026 | APPROVED |
Conditions
Permit Number - TC-RES-0326-01042
Permit Status: Inspections
Permit Description: Renovate 2nd Floor Bedrooms, Bathroom and Relocate Stairway
| Date | Description | Comments |
|---|---|---|
| 03/04/2026 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-RES-0326-01042
Permite Description: Renovate 2nd Floor Bedrooms, Bathroom and Relocate Stairway
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/25/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | 06/25/2026 Add fire caulking to top plate penetrations throughout, block air register vents on three sides, secure Romex electrical wires in upstairs closet, add exhaust fan duct in upstairs bathroom. Ensure drainage, waste, and vent piping is under test for 15min with no leaks. Verified framing per plan, however either add A34 clips to bottom of stair stringer to landing and LU hangers at top of stair stringer per detail 101 or revise plans to reflect changes. |
| 08/06/2026 | COT - RSPL - Plumbing Final | N/A | Not Ready |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-RES-0326-01042
Permit Description: Renovate 2nd Floor Bedrooms, Bathroom and Relocate Stairway
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/26/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 06/26/2026 Corrections made to prior inspection. |
|
| 08/06/2026 | RSBU - Building Final | Passed | ||
| 08/06/2026 | COT - RSEL - Electrical Final | Passed | ||
| 08/06/2026 | COT - RSME - Mechanical Final | Passed |