| 06/25/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | 06/25/2026 Add fire caulking to top plate penetrations throughout, block air register vents on three sides, secure Romex electrical wires in upstairs closet, add exhaust fan duct in upstairs bathroom. Ensure drainage, waste, and vent piping is under test for 15min with no leaks. Verified framing per plan, however either add A34 clips to bottom of stair stringer to landing and LU hangers at top of stair stringer per detail 101 or revise plans to reflect changes. |
|
| 06/26/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 06/26/2026 Corrections made to prior inspection. |