Permit Details

Status:
Complete
Type:
Residential Building - One or Two Family
Address:
1034 E PRINCE RD
Address NEW:
1034 E PRINCE RD
Apply Date:
03/14/2023
Applicant:
Andrew Cook
Description:
CE-VIO1122-00737 Remodel SFR

Permit Reviews

Permit Number - TC-RES-0323-03579
Permit Status: Complete
Permit Description: CE-VIO1122-00737 Remodel SFR
Start Date Submittal Complete Date Status  
05/17/2023 RESIDENTIAL NEW DWELLING v.2 06/16/2023 APPROVED Review Details
03/29/2023 RESIDENTIAL NEW DWELLING v.1 03/29/2023 REQUIRES RESUBMIT Review Details

Conditions

Permit Number - TC-RES-0323-03579
Permit Status: Complete
Permit Description: CE-VIO1122-00737 Remodel SFR
Date Description Comments
06/16/2023 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/integrated-planning/PDSD/PDSD_Owner_Builder_Affidavit.pdf, is required prior to issuance of permit.

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-RES-0323-03579
Permite Description: CE-VIO1122-00737 Remodel SFR
Total Outstanding Inspections - 5
Last Inspection Date Description Inspector Results Comments
07/11/2023 COT - RSPL - Plumbing Final N/A Re-inspection required
09/14/2023 RSBU - Building Final N/A Re-inspection required 9/14/23: all kitchen countertop reciprocals need to be GFCI protected, food compose and dishwasher reciprocal needs to be GFCI protected, smoke detectors not hard wired or interconnected, outlet at laundry room needs to be GFCI protected STOPPED INSPECTION
09/13/2023 COT - RSEL - Electrical Final N/A Re-inspection required Receptacles in kitchen need to be gfci. Missing receptacle at kitchen counter top, right of stove. Missing receptacle in hallway according to the plans. Along with one in the back yard. Receptacle in laundry room has a hot and neutral reversed. Missing a receptacle in laundry room as well according to plans. Check electrical plans to verify what is needed. 9/13/2023
07/17/2023 RSPL - Plumbing Progress N/A Partial Pass 7/17/23 interior looks good, under pressure. Need to complete outside sewer lines
04/29/2024 BULD - Electrical Clearance N/A Not Applicable

Completed Inspections

Permit Status: Complete
Permit Number: TC-RES-0323-03579
Permit Description: CE-VIO1122-00737 Remodel SFR
Total Completed Inspections - 10

Documents

File Name Document Type  
LOFC_LETTEROFCOMPLETION.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-PLAN SET_V1.PDF DOCUMENTS VIEW