Permit: TC-RES-0223-03160
Permit Details
Status:
Complete
Type:
Residential Building - One or Two Family
Address:
2326 N EMERALD LAKE CT
Address NEW:
2326 N EMERALD LAKE CT
Apply Date:
02/28/2023
Applicant:
Erik Myers
Description:
Fire Damage Repair
Permit Reviews
Permit Number - TC-RES-0223-03160
Permit Status: Complete
Permit Description: Fire Damage Repair
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/28/2023 | RESIDENTIAL NEW DWELLING v.1 | 03/28/2023 | APPROVED |
Conditions
Permit Number - TC-RES-0223-03160
Permit Status: Complete
Permit Description: Fire Damage Repair
| Date | Description | Comments |
|---|---|---|
| 03/28/2023 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/integrated-planning/PDSD/PDSD_Owner_Builder_Affidavit.pdf, is required prior to issuance of permit. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-RES-0223-03160
Permite Description: Fire Damage Repair
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/22/2023 | COT - RSBU - Roof Nailing | N/A | Not Applicable | |
| 09/12/2023 | RSBU - Building Final | N/A | Re-inspection required | 9/12/23: receptacle for dishwasher/food compose needs to be GFCI protected Receptacle for laundry needs to be GFCI protected |
Completed Inspections
Permit Status: Complete
Permit Number: TC-RES-0223-03160
Permit Description: Fire Damage Repair
Total Completed Inspections - 7
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/22/2023 | BULD - Electrical Clearance | Passed | ||
| 07/12/2023 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 6/22/23: seal all penetrations through top plate throughout home, gas line needs to be secured, plates in bathrooms and laundry having the purpose of protection of ABS have to be 5"x8". Over notched stud in bathroom needs stud-shoe. Open chase in kitchen needs to be sealed. Outdoor lighting needs to be grounded to metal boxes. All penetrations in vapor barrier need to be sealed. Range power supply needs to be made up in a box, return air box needs support on 3 sides. DWV are dry and tubs are dry. Exhaust in master bathroom needs proper termination to exterior of house. Exhaust fans need power supply ran to them. 7/12/23: all corrections made |
|
| 09/12/2023 | COT - BULD - SWG Clearance | Passed | SWG FOR RECONNECTION | |
| 09/12/2023 | COT - RSME - Mechanical Final | Passed | ||
| 09/12/2023 | COT - RSPL - Plumbing Final | Passed | ||
| 09/13/2023 | COT - RSEL - Electrical Final | Passed | ||
| 09/13/2023 | RSBU - Building Final | Passed |