Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Inspections
Type:
Residential Building - One or Two Family
Address NEW:
8128 E 4TH PL UNIT 2
Apply Date:
02/22/2023
Applicant:
RICK BRIGHT
Description:
Enclose Carport & Workshop into ADU without permit

Permit Reviews

Permit Number - TC-RES-0223-03025
Permit Status: Inspections
Permit Description: Enclose Carport & Workshop into ADU without permit
Start Date Submittal Complete Date Status  
04/28/2025 RESTAMP - RESIDENTIAL v.1 04/28/2025 APPROVED Review Details
08/25/2023 RESIDENTIAL NEW DWELLING v.2 08/25/2023 REQUIRES RESUBMIT Review Details
02/04/2025 RESIDENTIAL NEW DWELLING v.9 02/20/2025 REQUIRES RESUBMIT Review Details
09/05/2023 RESIDENTIAL NEW DWELLING v.3 09/28/2023 REQUIRES RESUBMIT Review Details
03/03/2025 RESIDENTIAL NEW DWELLING v.10 03/17/2025 REQUIRES RESUBMIT Review Details
07/12/2024 RESIDENTIAL NEW DWELLING v.7 07/15/2024 REQUIRES RESUBMIT Review Details
09/19/2024 RESIDENTIAL NEW DWELLING v.8 10/18/2024 REQUIRES RESUBMIT Review Details
04/23/2025 RESIDENTIAL NEW DWELLING v.11 04/28/2025 APPROVED Review Details
03/02/2023 RESIDENTIAL NEW DWELLING v.1 03/30/2023 REQUIRES RESUBMIT Review Details
04/04/2024 RESIDENTIAL NEW DWELLING v.4 04/04/2024 REQUIRES RESUBMIT Review Details
05/22/2024 RESIDENTIAL NEW DWELLING v.6 06/17/2024 REQUIRES RESUBMIT Review Details
04/04/2024 RESIDENTIAL NEW DWELLING v.5 05/03/2024 REQUIRES RESUBMIT Review Details

Conditions

Permit Number - TC-RES-0223-03025
Permit Status: Inspections
Permit Description: Enclose Carport & Workshop into ADU without permit
Date Description Comments
05/30/2024 Please contact Pima County Addressing to resolve issue. Addressing@pima.gov or 520-724-9512
02/04/2025 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-RES-0223-03025
Permite Description: Enclose Carport & Workshop into ADU without permit
Total Outstanding Inspections - 9
Last Inspection Date Description Inspector Results Comments
11/06/2025 RSBU - Building Final N/A Re-inspection required 1. Missing a smoke detector in sleeping area.

2. Dishwasher needs to be anchored down; dishwasher is missing waterhammer arrestor, dishwasher drain needs to be looped and supported.

3. Anti-tip on electric range is missing.

4. Two small appliance circuits are needed in kitchen.

5. Open up dead front on sub panel to verify proper wiring.

6. Remove washing machine to verify water hammer arrestors.

7. No exhaust for kitchen range

8. Mini split is not UL listed.
11/06/2025 COT - RSEL - Electrical Final N/A Re-inspection required 1. Loose receptacles throughout and missing wall plates.

2. Fridge and dishwasher must be on separate circuits.

3. exterior receptacle needs to be WR rated in Tamper resistant also requires proper wall plate.

4. EV receptacle needs to be pulled out to verify proper wiring size.
11/06/2025 COT - RSBU - Excavation/Rebar/Zoning N/A Not Applicable
11/06/2025 COT - RSEL - Grounding/Bonding N/A Re-inspection required Open up dead front on sub panel to verify proper wiring
11/06/2025 COT - RSBU - Roof Nailing N/A Re-inspection required 1. Open up a a few sections in ceiling(enough to allow inspector to look and see what's up drywall)to allow for roof rafter inspection.
11/06/2025 COT - RSBU - Preslab N/A Not Applicable
11/06/2025 COT - RSPL - Yard Water Line N/A Re-inspection required Dig up a small section outside to allow for water line inspection.
11/06/2025 COT - RSPL - Plumbing Final N/A Re-inspection required
11/06/2025 COT - RSPL - Rough Soil N/A Not Applicable

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-8128E4THPL - V2_V1_V1.PDF DOCUMENTS VIEW
CONS-CONS-SCHULDIES 2.24.25_V7_V1.PDF DOCUMENTS VIEW
PDSD_OWNER_BUILDER_AFFIDAVIT_V1.PDF DOCUMENTS VIEW