Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-RES-0223-03025
Permit Details
Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
8128 E 4TH PL UNIT 2
Address NEW:
8128 E 4TH PL UNIT 2
Apply Date:
02/22/2023
Applicant:
RICK BRIGHT
Description:
Enclose Carport & Workshop into ADU without permit
Permit Reviews
Permit Number - TC-RES-0223-03025
Permit Status: Inspections
Permit Description: Enclose Carport & Workshop into ADU without permit
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 04/28/2025 | RESTAMP - RESIDENTIAL v.1 | 04/28/2025 | APPROVED |
| 08/25/2023 | RESIDENTIAL NEW DWELLING v.2 | 08/25/2023 | REQUIRES RESUBMIT |
| 02/04/2025 | RESIDENTIAL NEW DWELLING v.9 | 02/20/2025 | REQUIRES RESUBMIT |
| 09/05/2023 | RESIDENTIAL NEW DWELLING v.3 | 09/28/2023 | REQUIRES RESUBMIT |
| 03/03/2025 | RESIDENTIAL NEW DWELLING v.10 | 03/17/2025 | REQUIRES RESUBMIT |
| 07/12/2024 | RESIDENTIAL NEW DWELLING v.7 | 07/15/2024 | REQUIRES RESUBMIT |
| 09/19/2024 | RESIDENTIAL NEW DWELLING v.8 | 10/18/2024 | REQUIRES RESUBMIT |
| 04/23/2025 | RESIDENTIAL NEW DWELLING v.11 | 04/28/2025 | APPROVED |
| 03/02/2023 | RESIDENTIAL NEW DWELLING v.1 | 03/30/2023 | REQUIRES RESUBMIT |
| 04/04/2024 | RESIDENTIAL NEW DWELLING v.4 | 04/04/2024 | REQUIRES RESUBMIT |
| 05/22/2024 | RESIDENTIAL NEW DWELLING v.6 | 06/17/2024 | REQUIRES RESUBMIT |
| 04/04/2024 | RESIDENTIAL NEW DWELLING v.5 | 05/03/2024 | REQUIRES RESUBMIT |
Conditions
Permit Number - TC-RES-0223-03025
Permit Status: Inspections
Permit Description: Enclose Carport & Workshop into ADU without permit
| Date | Description | Comments |
|---|---|---|
| 05/30/2024 | Please contact Pima County Addressing to resolve issue. Addressing@pima.gov or 520-724-9512 | |
| 02/04/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-RES-0223-03025
Permite Description: Enclose Carport & Workshop into ADU without permit
Total Outstanding Inspections - 9
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/06/2025 | RSBU - Building Final | N/A | Re-inspection required | 1. Missing a smoke detector in sleeping area. 2. Dishwasher needs to be anchored down; dishwasher is missing waterhammer arrestor, dishwasher drain needs to be looped and supported. 3. Anti-tip on electric range is missing. 4. Two small appliance circuits are needed in kitchen. 5. Open up dead front on sub panel to verify proper wiring. 6. Remove washing machine to verify water hammer arrestors. 7. No exhaust for kitchen range 8. Mini split is not UL listed. |
| 11/06/2025 | COT - RSEL - Electrical Final | N/A | Re-inspection required | 1. Loose receptacles throughout and missing wall plates. 2. Fridge and dishwasher must be on separate circuits. 3. exterior receptacle needs to be WR rated in Tamper resistant also requires proper wall plate. 4. EV receptacle needs to be pulled out to verify proper wiring size. |
| 11/06/2025 | COT - RSBU - Excavation/Rebar/Zoning | N/A | Not Applicable | |
| 11/06/2025 | COT - RSEL - Grounding/Bonding | N/A | Re-inspection required | Open up dead front on sub panel to verify proper wiring |
| 11/06/2025 | COT - RSBU - Roof Nailing | N/A | Re-inspection required | 1. Open up a a few sections in ceiling(enough to allow inspector to look and see what's up drywall)to allow for roof rafter inspection. |
| 11/06/2025 | COT - RSBU - Preslab | N/A | Not Applicable | |
| 11/06/2025 | COT - RSPL - Yard Water Line | N/A | Re-inspection required | Dig up a small section outside to allow for water line inspection. |
| 11/06/2025 | COT - RSPL - Plumbing Final | N/A | Re-inspection required | |
| 11/06/2025 | COT - RSPL - Rough Soil | N/A | Not Applicable |