Permit Details

Status:
Inspections
Type:
Residential Building - One or Two Family
Address NEW:
3704 S MANITOBA AV
Apply Date:
02/17/2023
Applicant:
Antonio Cruz
Description:
SFR

Permit Reviews

Permit Number - TC-RES-0223-02945
Permit Status: Inspections
Permit Description: SFR
Start Date Submittal Complete Date Status  
04/26/2023 RESIDENTIAL NEW DWELLING v.2 05/17/2023 APPROVED Review Details
03/02/2023 RESIDENTIAL NEW DWELLING v.1 03/23/2023 REQUIRES RESUBMIT Review Details

Outstanding Activity Conditions

Permit Number - TC-RES-0223-02945
Permit Status: Inspections
Permit Description: SFR
Total Outstanding Activity Conditions - 1
Date Name
03/15/2023 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Conditions

Permit Number - TC-RES-0223-02945
Permit Status: Inspections
Permit Description: SFR
Date Description Comments
05/17/2023 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/integrated-planning/PDSD/PDSD_Owner_Builder_Affidavit.pdf, is required prior to issuance of permit.
05/17/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-RES-0223-02945
Permite Description: SFR
Total Outstanding Inspections - 16
Last Inspection Date Description Inspector Results Comments
11/14/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Re-inspection required Not ready. Staples going through electrical lines and ABS. Add nail plates to anything that is less than an 1"1/4. Secure loose electrical lines. Secure exhaust vents. Smoke detector needs to be 6" away horizontal and vertically from the wall. Fire foam top penetrations. Top plates that been over notched need to have a 16 gage strap with minimum 8 nails on each end. Studs that been over notched due to plumbing need to have stud shoes. Hallway needs to be 36" at final. Receptacle at island are not in place. plans also call for a gas line to be installed. Too many issues. STOPPED INSPECTION. 11/14/2023
10/06/2023 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Re-inspection required Corrections incomplete.

South wall is less than 3' from property line, and does not meet the requirements of R302.1 as amended.
02/21/2025 COT - BULD - SWG Clearance N/A Re-inspection required 2/21/25: South wall is less than 3' from property line, and does not meet the requirements of R302.1 as amended. Residence is occupied without having a Certificate of Occupancy.
02/21/2025 COT - RSBU - Excavation/Rebar/Zoning N/A Re-inspection required 2/21/25: South wall is less than 3' from property line, and does not meet the requirements of R302.1 as amended. Residence is occupied without having a Certificate of Occupancy.
02/21/2025 COT - RSBU - Interior Shear Bracing N/A Re-inspection required 2/21/25: South wall is less than 3' from property line, and does not meet the requirements of R302.1 as amended. Residence is occupied without having a Certificate of Occupancy.
02/21/2025 RSBU - Building Final N/A Re-inspection required 2/21/25: South wall is less than 3' from property line, and does not meet the requirements of R302.1 as amended. Residence is occupied without having a Certificate of Occupancy.
02/21/2025 COT - RSBU - Roof Nailing N/A Re-inspection required 2/21/25: South wall is less than 3' from property line, and does not meet the requirements of R302.1 as amended. Residence is occupied without having a Certificate of Occupancy.
02/21/2025 COT - RSEL - Electrical Final N/A Re-inspection required 2/21/25: South wall is less than 3' from property line, and does not meet the requirements of R302.1 as amended. Residence is occupied without having a Certificate of Occupancy.
02/21/2025 COT - RSEL - Grounding/Bonding N/A Re-inspection required 2/21/25: South wall is less than 3' from property line, and does not meet the requirements of R302.1 as amended. Residence is occupied without having a Certificate of Occupancy.
02/21/2025 COT - RSEL - Outdoor Lighting N/A Re-inspection required 2/21/25: South wall is less than 3' from property line, and does not meet the requirements of R302.1 as amended. Residence is occupied without having a Certificate of Occupancy.
03/02/2025 COT - RSME - Mechanical Final N/A Re-inspection required 2/21/25: South wall is less than 3' from property line, and does not meet the requirements of R302.1 as amended. Residence is occupied without having a Certificate of Occupancy.
02/21/2025 COT - RSPL - Gas Pressure Test N/A Re-inspection required 2/21/25: South wall is less than 3' from property line, and does not meet the requirements of R302.1 as amended. Residence is occupied without having a Certificate of Occupancy.
02/21/2025 COT - RSPL - Plumbing Final N/A Re-inspection required 2/21/25: South wall is less than 3' from property line, and does not meet the requirements of R302.1 as amended. Residence is occupied without having a Certificate of Occupancy.
02/21/2025 COT - RSPL - Rough Soil N/A Re-inspection required 2/21/25: South wall is less than 3' from property line, and does not meet the requirements of R302.1 as amended. Residence is occupied without having a Certificate of Occupancy.
02/21/2025 COT - RSPL - Sewer N/A Re-inspection required 2/21/25: South wall is less than 3' from property line, and does not meet the requirements of R302.1 as amended. Residence is occupied without having a Certificate of Occupancy.
02/21/2025 COT - RSPL - Yard Water Line N/A Re-inspection required 2/21/25: South wall is less than 3' from property line, and does not meet the requirements of R302.1 as amended. Residence is occupied without having a Certificate of Occupancy.

Completed Inspections

Permit Status: Inspections
Permit Number: TC-RES-0223-02945
Permit Description: SFR
Total Completed Inspections - 3
Date Description Inspector Results Comments
12/22/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 12-22-23: All previous inspection notes have been corrected. Okay to proceed with insulation and drywall work.
03/05/2024 BULD - Electrical Clearance Passed Approved new service panel, ECO Clearance to TEP is required
02/21/2025 COT - RSEL - Electrical Underground Passed 2/21/25: South wall is less than 3' from property line, and does not meet the requirements of R302.1 as amended. Residence is occupied without having a Certificate of Occupancy.

Documents

File Name Document Type  
3704PDSD_OWNER_BUILDER_AFFIDAVIT_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
MURDOCK DEV HVAC MANUAL J CALCS_V1.PDF DOCUMENTS VIEW
CONS-MURDOCK MANITOBA SITE 3704 REV_V2.PDF DOCUMENTS VIEW
MURDOCK 1600 REV_V2.PDF DOCUMENTS VIEW