Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Residential Building - One or Two Family
Address NEW:
10330 E SPEEDWAY BL
Apply Date:
02/15/2023
Applicant:
Aiden Hankel
Description:
SFR R1: Updated truss and HVAC

Permit Reviews

Permit Number - TC-RES-0223-02892
Permit Status: Complete
Permit Description: SFR R1: Updated truss and HVAC
Start Date Submittal Complete Date Status  
07/29/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 07/30/2024 REQUIRES RESUBMIT Review Details
03/01/2023 RESIDENTIAL NEW DWELLING v.1 04/04/2023 APPROVED Review Details
08/25/2023 RESIDENTIAL NEW DWELLING v.1 08/25/2023 REQUIRES RESUBMIT Review Details
12/13/2023 RESIDENTIAL NEW DWELLING v.2 01/03/2024 APPROVED Review Details
08/05/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.2 08/05/2024 REQUIRES RESUBMIT Review Details
08/20/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 08/22/2024 APPROVED Review Details
08/09/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.3 08/14/2024 APPROVED Review Details
08/16/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 08/19/2024 APPROVED Review Details

Conditions

Permit Number - TC-RES-0223-02892
Permit Status: Complete
Permit Description: SFR R1: Updated truss and HVAC
Date Description Comments
04/04/2023 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/integrated-planning/PDSD/PDSD_Owner_Builder_Affidavit.pdf, is required prior to issuance of permit.
03/13/2023 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
04/05/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
08/15/2024 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.
03/13/2023 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-RES-0223-02892
Permite Description: SFR R1: Updated truss and HVAC
Total Outstanding Inspections - 5
Last Inspection Date Description Inspector Results Comments
08/01/2023 COT - RSEL - Grounding/Bonding N/A Deferred
04/22/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Not Ready Remove all insulation and netting from framing to allow inspection.
03/20/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Partial Pass Provide verification from Engineer of Record that hanger in garage is adequate to support load imposed by two-ply girder to Microlam, that microlam connection(s) to I-joists at cantilever are adequate to transmit gravity loads imposed by garage trusses and girder connected to microlam by hangers to the bearing wall, and that platform framing in great room is acceptable in lieu of the balloon framing shown on plans.

OK to proceed at own risk; reschedule with Intermediate, or before if additional requested engineering does not support proceeding.
04/05/2024 COT - RSPL - Sewer N/A Not Applicable Septic line from house.
06/25/2024 COT - RSEL - Electrical Final N/A Not Ready

Completed Inspections

Permit Status: Complete
Permit Number: TC-RES-0223-02892
Permit Description: SFR R1: Updated truss and HVAC
Total Completed Inspections - 21
Date Description Inspector Results Comments
09/05/2023 COT - RSBU - Preslab Passed 9/5/23: all corrections made
03/19/2024 COT - RSPL - Yard Water Line Passed
03/20/2024 COT - RSBU - Roof Nailing Passed
04/24/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 4/24/24: all netting and insulation have been removed for inspection. Simpson hanger has been added to support beam in garage and full span ledger board has been installed to end of TJI Floor joists for 2nd floor. All mechanical, electrical, and plumbing rough-in is complete. Okay to proceed with installation of insulation and drywall on entire house.
05/09/2024 COT - RSBU - Interior Shear Bracing Passed
05/20/2024 BULD - Electrical Clearance Passed
07/12/2024 COT - RSPL - Gas Pressure Test Passed Gas line is holding 15# of air with no leaks. Okay to proceed.
07/12/2024 COT - BULD - SWG Clearance Passed Gas line is holding 15# of air with no leaks. SWG Clearance is being issued to Southwest Gas. Okay to install meter and turn on gas.
07/29/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed Passed 4/24/24 by R. Mellecker.
07/29/2024 COT - RSEL - Electrical Underground Passed
07/29/2024 RSPL - Plumbing Progress Passed
07/29/2024 COT - RSPL - Sewer Passed Not Applicable house is on its own septic system.
07/29/2024 COT - RSPL - Plumbing Final Passed Construction, mechanical, electrical, plumbing, fire suppression/alarm work is complete. Mechanical, electrical, and plumbing fixtures are installed and functioning correctly. Main and sub-panel are properly installed and labeled, with AFCI & GFCI breakers installed for required outlets. A/C registers and thermostats are installed. Okay to issue Certificate of Occupancy for this permit.
07/29/2024 COT - RSME - Mechanical Final Passed Construction, mechanical, electrical, plumbing, fire suppression/alarm work is complete. Mechanical, electrical, and plumbing fixtures are installed and functioning correctly. Main and sub-panel are properly installed and labeled, with AFCI & GFCI breakers installed for required outlets. A/C registers and thermostats are installed. Okay to issue Certificate of Occupancy for this permit.
07/29/2024 COT - RSEL - Electrical Final Passed Construction, mechanical, electrical, plumbing, fire suppression/alarm work is complete. Mechanical, electrical, and plumbing fixtures are installed and functioning correctly. Main and sub-panel are properly installed and labeled, with AFCI & GFCI breakers installed for required outlets. A/C registers and thermostats are installed. Okay to issue Certificate of Occupancy for this permit.
07/29/2024 RSBU - Building Final Passed Construction, mechanical, electrical, plumbing, fire suppression/alarm work is complete. Mechanical, electrical, and plumbing fixtures are installed and functioning correctly. Main and sub-panel are properly installed and labeled, with AFCI & GFCI breakers installed for required outlets. A/C registers and thermostats are installed. Okay to issue Certificate of Occupancy for this permit.
08/02/2024 COT - FCON - Fire - Final Passed
08/16/2024 COT - RSEL - Outdoor Lighting Passed Outdoor lighting is properly installed per plans and meets city requirements.
08/16/2024 COT - RSBU - Excavation/Rebar/Zoning Passed
08/21/2024 COT - FCON - Sprinkler - Final Passed Approved on 7/15/2024 on permit #TF-FCP-0324-00170
08/21/2024 COT - RSPL - Rough Soil Passed Submit letter from licensed contractor on company letterhead taking responsibility for the work included in this inspection. Letter has been submitted. EWS

Documents

File Name Document Type  
COFO_FINALCOFO_RESIDENTIAL.PDF DOCUMENTS VIEW
SPECIAL INSPECTION-2024-08-08_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-REV. 1 -RESUBMITTAL_V1.PDF DOCUMENTS VIEW
FAIRWAY HOMES TOLLEY 3286 PINEHURST REV1 REPORT DEC 5 2023_V1.PDF DOCUMENTS VIEW
PERMIT REVISION LETTER_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
220541 - STAMPED - ENG CALCS - 12.30.2022_V1.PDF DOCUMENTS VIEW
220541 - STAMPED - ENG SHEETS - 12.30.2022_V1.PDF DOCUMENTS VIEW
CONS-TOLLEY, CHRIS - TIFFANY - 3286 PINEHURST (8)_V1.PDF DOCUMENTS VIEW
FAIRWAY HOMES TOLLEY 3286 PINEHURST REPORT FEB 4 2023_V1.PDF DOCUMENTS VIEW
SOILS TESTING_V1.PDF DOCUMENTS VIEW
TOLLEY SITE PLAN (ORTHO)_V3_V1.PDF DOCUMENTS VIEW