Parcel: 13337010A


Addresses:

10330 E SPEEDWAY BL


Inspection Status: Partial Pass

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Permit Number - TC-RES-0223-02892

Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Inspection Status - Partial Pass

Date Description Inspector Results Comments
03/20/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Partial Pass Provide verification from Engineer of Record that hanger in garage is adequate to support load imposed by two-ply girder to Microlam, that microlam connection(s) to I-joists at cantilever are adequate to transmit gravity loads imposed by garage trusses and girder connected to microlam by hangers to the bearing wall, and that platform framing in great room is acceptable in lieu of the balloon framing shown on plans.

OK to proceed at own risk; reschedule with Intermediate, or before if additional requested engineering does not support proceeding.
04/22/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Not Ready Remove all insulation and netting from framing to allow inspection.
04/24/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 4/24/24: all netting and insulation have been removed for inspection. Simpson hanger has been added to support beam in garage and full span ledger board has been installed to end of TJI Floor joists for 2nd floor. All mechanical, electrical, and plumbing rough-in is complete. Okay to proceed with installation of insulation and drywall on entire house.
07/29/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed Passed 4/24/24 by R. Mellecker.