Permit: TC-RES-0126-00142
Permit Details
Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
7308 E EASTVIEW DR
Address NEW:
7308 E EASTVIEW DR
Apply Date:
01/12/2026
Applicant:
Delta Mechanical
Description:
Replace 40 gal 36k btu gas water heater like for like
Permit Reviews
Permit Number - TC-RES-0126-00142
Permit Status: Inspections
Permit Description: Replace 40 gal 36k btu gas water heater like for like
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/12/2026 | RESIDENTIAL SIMPLE REVIEW v.1 | 01/13/2026 | APPROVED |
Conditions
Permit Number - TC-RES-0126-00142
Permit Status: Inspections
Permit Description: Replace 40 gal 36k btu gas water heater like for like
| Date | Description | Comments |
|---|---|---|
| 01/12/2026 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-RES-0126-00142
Permite Description: Replace 40 gal 36k btu gas water heater like for like
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/22/2026 | COT - RSPL - Plumbing Final | N/A | Re-inspection required | 01/22/2026 Temp and pressure relief valve must be gravity drained. Currently the T&P valve discharge pipe loops above valve and out to a wall, to which could not verify if terminated outdoors. No carbon monoxide detector installed, this is required since gas water heater is in the house. Provide drain pan to prevent leakage damage in the house. |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-RES-0126-00142
Permit Description: Replace 40 gal 36k btu gas water heater like for like
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/04/2026 | COT - RSPL - Plumbing Final | Passed | 02/04/2026 Approved per plan. All corrections made to 1/22/26 inspection. |