Permit: TC-RES-0125-00570
Permit Details
Status:
Inspections
Type:
Residential Building - One or Two Family
Address:
2025 S CAMILLA SV
Address NEW:
2025 S CAMILLA SV
Apply Date:
01/29/2025
Applicant:
Angel Rascon
Description:
We are removing old none grounded wire and running new wire with ground. GFCI protected circuits are being added to the bathroom and to the kitchen. Dedicated circuit for smoke detectors will be added also. No additional outlets have been added, electrical layout is the same, we are just running new grounded wire. MC cable is being used in areas that will be covered by plaster. Attached is a schematic of the home with panel schedule and load calculations. Nothing is being done to current 200amp panel. Panel is to remain the same. Old fused sub panel is being removed And all load circuits are directed to main panel.
Permit Reviews
Permit Number - TC-RES-0125-00570
Permit Status: Inspections
Permit Description: We are removing old none grounded wire and running new wire with ground. GFCI protected circuits are being added to the bathroom and to the kitchen. Dedicated circuit for smoke detectors will be added also. No additional outlets have been added, electrical layout is the same, we are just running new grounded wire. MC cable is being used in areas that will be covered by plaster. Attached is a schematic of the home with panel schedule and load calculations. Nothing is being done to current 200amp panel. Panel is to remain the same. Old fused sub panel is being removed And all load circuits are directed to main panel.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/31/2025 | RESIDENTIAL SIMPLE REVIEW v.2 | 02/01/2025 | REQUIRES RESUBMIT |
| 02/03/2025 | RESIDENTIAL SIMPLE REVIEW v.3 | 02/03/2025 | APPROVED |
| 01/30/2025 | RESIDENTIAL SIMPLE REVIEW v.1 | 01/30/2025 | REQUIRES RESUBMIT |
Conditions
Permit Number - TC-RES-0125-00570
Permit Status: Inspections
Permit Description: We are removing old none grounded wire and running new wire with ground. GFCI protected circuits are being added to the bathroom and to the kitchen. Dedicated circuit for smoke detectors will be added also. No additional outlets have been added, electrical layout is the same, we are just running new grounded wire. MC cable is being used in areas that will be covered by plaster. Attached is a schematic of the home with panel schedule and load calculations. Nothing is being done to current 200amp panel. Panel is to remain the same. Old fused sub panel is being removed And all load circuits are directed to main panel.
| Date | Description | Comments |
|---|---|---|
| 01/30/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-RES-0125-00570
Permite Description: We are removing old none grounded wire and running new wire with ground. GFCI protected circuits are being added to the bathroom and to the kitchen. Dedicated circuit for smoke detectors will be added also. No additional outlets have been added, electrical layout is the same, we are just running new grounded wire. MC cable is being used in areas that will be covered by plaster. Attached is a schematic of the home with panel schedule and load calculations. Nothing is being done to current 200amp panel. Panel is to remain the same. Old fused sub panel is being removed And all load circuits are directed to main panel.
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/07/2025 | BULD - Electrical Clearance | N/A | Not Applicable | duplicate |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-RES-0125-00570
Permit Description: We are removing old none grounded wire and running new wire with ground. GFCI protected circuits are being added to the bathroom and to the kitchen. Dedicated circuit for smoke detectors will be added also. No additional outlets have been added, electrical layout is the same, we are just running new grounded wire. MC cable is being used in areas that will be covered by plaster. Attached is a schematic of the home with panel schedule and load calculations. Nothing is being done to current 200amp panel. Panel is to remain the same. Old fused sub panel is being removed And all load circuits are directed to main panel.
Total Completed Inspections - 2
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/07/2025 | RSEL - Electrical Progress | Passed | rough in | |
| 10/14/2025 | COT - RSEL - Electrical Final | Passed | 10.14.2025 Approved, per plan. |