Permit Reviews
Permit Number - TC-RES-0125-00234
Permit Status: Complete
Permit Description: 2ND STORY EXTERIOR STAIRS
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/29/2025 | RESIDENTIAL NEW DWELLING v.1 | 03/03/2025 | APPROVED |
Conditions
Permit Number - TC-RES-0125-00234
Permit Status: Complete
Permit Description: 2ND STORY EXTERIOR STAIRS
| Date | Description | Comments |
|---|---|---|
| 01/29/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-RES-0125-00234
Permite Description: 2ND STORY EXTERIOR STAIRS
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/24/2025 | RSBU - Building Final | N/A | Re-inspection required | 24 March 25 1. Openings in risers are greater than 4". Per IRC 2018; R311.7.5.1--At open risers, openings located more than 30 inches (762 mm), as measured vertically, to the floor or grade below shall not permit the passage of a 4-inch-diameter (102 mm) sphere. 2. Handrails are too wide; handrails must have graspable shape typically circular 1-1/4"- 2" diameter. 3. Top 2 risers leading into patio have a height difference of almost 1", you cannot have a risers vary more than 3/8" in height. |
| 03/24/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | 24 March 25 1. Openings in risers are greater than 4". Per IRC 2018; R311.7.5.1--At open risers, openings located more than 30 inches (762 mm), as measured vertically, to the floor or grade below shall not permit the passage of a 4-inch-diameter (102 mm) sphere. 2. Handrails are too wide; handrails must have graspable shape typically circular 1-1/4"- 2" diameter. 3. Top 2 risers leading into patio have a height difference of almost 1", you cannot have a risers vary more than 3/8" in height. |
Completed Inspections
Permit Status: Complete
Permit Number: TC-RES-0125-00234
Permit Description: 2ND STORY EXTERIOR STAIRS
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/10/2025 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
| 04/02/2025 | RSBU - Building Final | Passed | 4/2/2025 Approved. All corrections have been made. | |
| 04/02/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 4/2/2025 Approved. All corrections have been made. |