Permit Details

Status:
Complete
Type:
Residential Building - One or Two Family
Address NEW:
2060 W PROBASCO DR
Apply Date:
01/19/2023
Applicant:
Inai Maldonado
Description:
SFR

Permit Reviews

Permit Number - TC-RES-0123-02257
Permit Status: Complete
Permit Description: SFR
Start Date Submittal Complete Date Status  
05/04/2023 RESIDENTIAL NEW DWELLING v.2 05/17/2023 REQUIRES RESUBMIT Review Details
06/13/2023 RESTAMP - RESIDENTIAL v.1 06/15/2023 APPROVED Review Details
06/04/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 06/07/2024 APPROVED Review Details
02/28/2023 RESIDENTIAL NEW DWELLING v.1 03/23/2023 REQUIRES RESUBMIT Review Details
06/08/2023 RESIDENTIAL NEW DWELLING v.3 06/13/2023 APPROVED Review Details

Conditions

Permit Number - TC-RES-0123-02257
Permit Status: Complete
Permit Description: SFR
Date Description Comments
06/15/2023 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/integrated-planning/PDSD/PDSD_Owner_Builder_Affidavit.pdf, is required prior to issuance of permit.
06/04/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-RES-0123-02257
Permite Description: SFR
Total Outstanding Inspections - 4
Last Inspection Date Description Inspector Results Comments
07/18/2023 COT - RSBU - Excavation/Rebar/Zoning N/A Not Applicable
05/17/2024 COT - FCON - Sprinkler - Final N/A Partial Pass Bell did not ring.
06/12/2024 COT - BULD - SWG Clearance N/A Not Applicable
10/23/2023 COT - RSPL - Gas Pressure Test N/A Partial Pass

Completed Inspections

Permit Status: Complete
Permit Number: TC-RES-0123-02257
Permit Description: SFR
Total Completed Inspections - 15
Date Description Inspector Results Comments
08/04/2023 COT - RSBU - Preslab Passed
09/15/2023 COT - RSBU - Roof Nailing Passed
02/01/2024 COT - RSPL - Gas Final Passed
04/04/2024 COT - RSEL - Grounding/Bonding Passed
05/17/2024 COT - RSEL - Electrical Final Passed 4/4/24: Address missing at house, Vacuum breaker missing at hose bibs, electrical fixtures on exterior need to be made up, sprinkler system not hooked up, Water meter not installed at time of inspection, hose bibs need to be properly insulated and wrapped for up protection, clean outs need to be capped and cut to grade, Dining room breaker must be ARC-FAULT, Kitchen breakers must be ARC-FAULT, piping on exterior of house needs to be coated for UV protection, GFCI at laundry not functioning properly. water hammer arrestor missing throughout, bathroom Receptacles need to be GFCI, Receptacle under kitchen sink must be GFCI, HVAC drain line must be UV coated, Main door not installed at time of final inspection. No ladder for attic access.
5/17/24: corrections made.
05/17/2024 COT - RSEL - Outdoor Lighting Passed
05/17/2024 COT - RSME - Mechanical Final Passed 4/4/24: Address missing at house, Vacuum breaker missing at hose bibs, electrical fixtures on exterior need to be made up, sprinkler system not hooked up, Water meter not installed at time of inspection, hose bibs need to be properly insulated and wrapped for up protection, clean outs need to be capped and cut to grade, Dining room breaker must be ARC-FAULT, Kitchen breakers must be ARC-FAULT, piping on exterior of house needs to be coated for UV protection, GFCI at laundry not functioning properly. water hammer arrestor missing throughout, bathroom Receptacles need to be GFCI, Receptacle under kitchen sink must be GFCI, HVAC drain line must be UV coated, Main door not installed at time of final inspection. No ladder for attic access.
5/17/24: corrections made.
05/17/2024 COT - RSPL - Plumbing Final Passed 4/4/24: Address missing at house, Vacuum breaker missing at hose bibs, electrical fixtures on exterior need to be made up, sprinkler system not hooked up, Water meter not installed at time of inspection, hose bibs need to be properly insulated and wrapped for up protection, clean outs need to be capped and cut to grade, Dining room breaker must be ARC-FAULT, Kitchen breakers must be ARC-FAULT, piping on exterior of house needs to be coated for UV protection, GFCI at laundry not functioning properly. water hammer arrestor missing throughout, bathroom Receptacles need to be GFCI, Receptacle under kitchen sink must be GFCI, HVAC drain line must be UV coated, Main door not installed at time of final inspection. No ladder for attic access.
5/17/24: corrections made.
06/12/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed
06/12/2024 COT - RSBU - Interior Shear Bracing Passed
06/12/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed
06/12/2024 COT - RSEL - Electrical Underground Passed
06/12/2024 COT - RSPL - Rough Soil Passed
06/12/2024 COT - RSPL - Yard Water Line Passed
06/12/2024 RSBU - Building Final Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
DO-NOT-REPLY_20240604_132548_V1.PDF DOCUMENTS VIEW
SCAN_RIBARRA1_2024-06-04-13-37-56_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-3_CORRECTED_PLAN_SET_V1.PDF DOCUMENTS VIEW
2060 W PROBASCO DR - RESP LTR._V1.PDF DOCUMENTS VIEW
1_DEED_SCAN JUN 8, 2023_V1.PDF DOCUMENTS VIEW
2_ROWE_SCAN JUN 8, 2023 (1)_V1.PDF DOCUMENTS VIEW
2060 W PROBASCO DR - RESP LTR._V1.PDF DOCUMENTS VIEW
2060 W. PROBASCO DR - MR AND MRS VALDIBA-PDF_V2.PDF DOCUMENTS VIEW
AHRI CERT - GOODMAN GPH1448M41A PKG HP 4 TON_V2.PDF DOCUMENTS VIEW
CONS-2_REV_PLAN_SET_V2.PDF DOCUMENTS VIEW
GOODMAN GPH14 SPECS (11)_V2.PDF DOCUMENTS VIEW