Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-MDP-1224-01407
Permit Details
Status:
Inspections Complete
Type:
Model Building Permit
Address:
9522 E WYNALDA DR
Address NEW:
9522 E WYNALDA DR
Apply Date:
12/20/2024
Applicant:
Celina Rodriguez
Description:
KB Home 1768 (Model Master Plan TC-MDP-1124-01303)
Permit Reviews
Permit Number - TC-MDP-1224-01407
Permit Status: Inspections complete
Permit Description: KB Home 1768 (Model Master Plan TC-MDP-1124-01303)
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 02/28/2025 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 03/17/2025 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-1224-01407
Permit Status: Inspections complete
Permit Description: KB Home 1768 (Model Master Plan TC-MDP-1124-01303)
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 12/23/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/ |
Conditions
Permit Number - TC-MDP-1224-01407
Permit Status: Inspections complete
Permit Description: KB Home 1768 (Model Master Plan TC-MDP-1124-01303)
| Date | Description | Comments |
|---|---|---|
| 02/28/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. | |
| 12/23/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-1224-01407
Permite Description: KB Home 1768 (Model Master Plan TC-MDP-1124-01303)
Total Outstanding Inspections - 6
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/10/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Re-inspection required | Add anchor bolts per shear wall schedule. Add nails at ledger near entry way. Double studs need to be underneath girder trusses at powder room. Blocking needs corrections at bearing trusses. Add studs underneath girder truss 1st floor for continuous load transfer. Truss FG5 calls for 3 bearing points. Add h25 and supports. Floor trusses that call for bearing points need to be shimmed. Stopped inspection other items may apply. 4/10/2025 |
| 04/10/2025 | COT - RSBU - Roof Nailing | N/A | Re-inspection required | Add anchor bolts per shear wall schedule. Add nails at ledger near entry way. Double studs need to be underneath girder trusses at powder room. Blocking needs corrections at bearing trusses. Add studs underneath girder truss 1st floor for continuous load transfer. Truss FG5 calls for 3 bearing points. Add h25 and supports. Floor trusses that call for bearing points need to be shimmed. Stopped inspection other items may apply. 4/10/2025 |
| 04/24/2025 | COT - BULD - SWG Clearance | N/A | Not Applicable | Site does not use gas |
| 03/26/2025 | COT - RSEL - Grounding/Bonding | N/A | Partial Pass | 26 March 25 Partial pass for UFER. |
| 04/24/2025 | COT - RSPL - Gas Pressure Test | N/A | Not Applicable | Site does not use gas |
| 04/24/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | Fire foam and caulk marked areas, move thermostat to 48" |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-1224-01407
Permit Description: KB Home 1768 (Model Master Plan TC-MDP-1124-01303)
Total Completed Inspections - 19
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/19/2025 | COT - RSPL - Rough Soil | Passed | Passed 3/19/25 ok to backfill | |
| 03/19/2025 | COT - RSPL - Sewer | Passed | Passed 3/19/25 ok to backfill | |
| 03/19/2025 | COT - RSPL - Yard Water Line | Passed | Passed 3/19/25 ok to backfill | |
| 03/26/2025 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
| 03/26/2025 | COT - RSBU - Preslab | Passed | ||
| 03/26/2025 | COT - RSEL - Electrical Underground | Passed | ||
| 04/15/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 4/15/25 corrections made | |
| 04/15/2025 | COT - RSBU - Roof Nailing | Passed | 4/15/25 corrections made | |
| 04/24/2025 | BULD - Electrical Clearance | Passed | Passed 4/24/24 ready for temp power | |
| 04/24/2025 | COT - RSEL - Grounding/Bonding | Passed | 4/24/24 connection made | |
| 04/25/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 4-25-25, residential intermediate inspection approved. Okay to continue with construction | |
| 05/06/2025 | COT - RSBU - Interior Shear Bracing | Passed | ||
| 08/19/2025 | ENGR Engineering Final | Passed | ||
| 08/19/2025 | RSBU - Building Progress | Passed | ||
| 08/21/2025 | COT - RSEL - Electrical Final | Passed | 8.21.25 Corrections made |
|
| 08/21/2025 | COT - RSEL - Outdoor Lighting | Passed | 8.21.25 approved |
|
| 08/21/2025 | COT - RSME - Mechanical Final | Passed | 8.21.25 Corrections made |
|
| 08/21/2025 | COT - RSPL - Plumbing Final | Passed | 8.21.25 approved |
|
| 08/21/2025 | RSBU - Building Final | Passed | 8.21.25 approved |