Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Inspections Complete
Type:
Model Building Permit
Address NEW:
9522 E WYNALDA DR
Apply Date:
12/20/2024
Applicant:
Celina Rodriguez
Description:
KB Home 1768 (Model Master Plan TC-MDP-1124-01303)

Permit Reviews

Permit Number - TC-MDP-1224-01407
Permit Status: Inspections complete
Permit Description: KB Home 1768 (Model Master Plan TC-MDP-1124-01303)
Start Date Submittal Complete Date Status  
02/28/2025 SITE FROM MODEL PERMIT - PRODUCTION v.1 03/17/2025 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-MDP-1224-01407
Permit Status: Inspections complete
Permit Description: KB Home 1768 (Model Master Plan TC-MDP-1124-01303)
Total Outstanding Activity Conditions - 1
Date Name
12/23/2024 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/

Conditions

Permit Number - TC-MDP-1224-01407
Permit Status: Inspections complete
Permit Description: KB Home 1768 (Model Master Plan TC-MDP-1124-01303)
Date Description Comments
02/28/2025 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.
12/23/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.

Outstanding Inspections

Permit Status: Inspections Complete
Permit Number: TC-MDP-1224-01407
Permite Description: KB Home 1768 (Model Master Plan TC-MDP-1124-01303)
Total Outstanding Inspections - 6
Last Inspection Date Description Inspector Results Comments
04/10/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Re-inspection required Add anchor bolts per shear wall schedule. Add nails at ledger near entry way. Double studs need to be underneath girder trusses at powder room. Blocking needs corrections at bearing trusses. Add studs underneath girder truss 1st floor for continuous load transfer. Truss FG5 calls for 3 bearing points. Add h25 and supports. Floor trusses that call for bearing points need to be shimmed. Stopped inspection other items may apply. 4/10/2025
04/10/2025 COT - RSBU - Roof Nailing N/A Re-inspection required Add anchor bolts per shear wall schedule. Add nails at ledger near entry way. Double studs need to be underneath girder trusses at powder room. Blocking needs corrections at bearing trusses. Add studs underneath girder truss 1st floor for continuous load transfer. Truss FG5 calls for 3 bearing points. Add h25 and supports. Floor trusses that call for bearing points need to be shimmed. Stopped inspection other items may apply. 4/10/2025
04/24/2025 COT - BULD - SWG Clearance N/A Not Applicable Site does not use gas
03/26/2025 COT - RSEL - Grounding/Bonding N/A Partial Pass 26 March 25
Partial pass for UFER.
04/24/2025 COT - RSPL - Gas Pressure Test N/A Not Applicable Site does not use gas
04/24/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Re-inspection required Fire foam and caulk marked areas, move thermostat to 48"

Completed Inspections

Permit Status: Inspections Complete
Permit Number: TC-MDP-1224-01407
Permit Description: KB Home 1768 (Model Master Plan TC-MDP-1124-01303)
Total Completed Inspections - 19
Date Description Inspector Results Comments
03/19/2025 COT - RSPL - Rough Soil Passed Passed 3/19/25 ok to backfill
03/19/2025 COT - RSPL - Sewer Passed Passed 3/19/25 ok to backfill
03/19/2025 COT - RSPL - Yard Water Line Passed Passed 3/19/25 ok to backfill
03/26/2025 COT - RSBU - Excavation/Rebar/Zoning Passed
03/26/2025 COT - RSBU - Preslab Passed
03/26/2025 COT - RSEL - Electrical Underground Passed
04/15/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 4/15/25 corrections made
04/15/2025 COT - RSBU - Roof Nailing Passed 4/15/25 corrections made
04/24/2025 BULD - Electrical Clearance Passed Passed 4/24/24 ready for temp power
04/24/2025 COT - RSEL - Grounding/Bonding Passed 4/24/24 connection made
04/25/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 4-25-25, residential intermediate inspection approved. Okay to continue with construction
05/06/2025 COT - RSBU - Interior Shear Bracing Passed
08/19/2025 ENGR Engineering Final Passed
08/19/2025 RSBU - Building Progress Passed
08/21/2025 COT - RSEL - Electrical Final Passed 8.21.25
Corrections made
08/21/2025 COT - RSEL - Outdoor Lighting Passed 8.21.25
approved
08/21/2025 COT - RSME - Mechanical Final Passed 8.21.25
Corrections made
08/21/2025 COT - RSPL - Plumbing Final Passed 8.21.25
approved
08/21/2025 RSBU - Building Final Passed 8.21.25
approved

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
MIRADOR POINT - LOT 162 START_V1.PDF DOCUMENTS VIEW
MP 162 SIC-2025-02-27_V1.PDF DOCUMENTS VIEW