Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Roof Nailing 

Permit Number - TC-MDP-1224-01407

Inspection Description - COT - RSBU - Roof Nailing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
04/10/2025 COT - RSBU - Roof Nailing  Re-inspection required Add anchor bolts per shear wall schedule. Add nails at ledger near entry way. Double studs need to be underneath girder trusses at powder room. Blocking needs corrections at bearing trusses. Add studs underneath girder truss 1st floor for continuous load transfer. Truss FG5 calls for 3 bearing points. Add h25 and supports. Floor trusses that call for bearing points need to be shimmed. Stopped inspection other items may apply. 4/10/2025
04/15/2025 COT - RSBU - Roof Nailing  Passed 4/15/25 corrections made