Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Model Building Permit
Apply Date:
01/05/2024
Applicant:
Daria Hopkins
Description:
SFR MER1301600 T21-M0073 REV1 roof covering change

Permit Reviews

Permit Number - TC-MDP-1223-01912
Permit Status: Complete
Permit Description: SFR MER1301600 T21-M0073 REV1 roof covering change
Start Date Submittal Complete Date Status  
09/26/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 09/27/2024 APPROVED Review Details
01/05/2024 SITE FROM MODEL PERMIT - PRODUCTION v.1 01/11/2024 APPROVED Review Details
06/27/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 06/28/2024 APPROVED Review Details

Conditions

Permit Number - TC-MDP-1223-01912
Permit Status: Complete
Permit Description: SFR MER1301600 T21-M0073 REV1 roof covering change
Date Description Comments
01/05/2024 SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED.
01/05/2024 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
01/05/2024 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
01/09/2024 Post-Tension Inspection Report is required.
01/05/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
06/28/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
01/05/2024 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.
06/28/2024 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.
06/28/2024 SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED.
01/09/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Completed Inspections

Permit Status: Complete
Permit Number: TC-MDP-1223-01912
Permit Description: SFR MER1301600 T21-M0073 REV1 roof covering change
Total Completed Inspections - 22
Date Description Inspector Results Comments
04/12/2024 COT - RSPL - Yard Water Line Passed
04/12/2024 COT - RSPL - Sewer Passed
04/12/2024 COT - RSPL - Rough Soil Passed
04/12/2024 COT - RSPL - Backwater Valve Passed
05/06/2024 COT - RSBU - Preslab Passed Concrete forms are set, masa clips are spaced properly, shear wall clips are in place per plans, rebar reinforcement is in place per plans, post tension cabling is installed and properly spaced per plans, plumbing pipes are properly wrapped with foam for protection, underground electrical for kitchen island is installed, and Ufer ground is installed on right side of garage. Okay to pour concrete for footings and slab on grade.
05/06/2024 COT - RSEL - Electrical Underground Passed Concrete forms are set, masa clips are spaced properly, shear wall clips are in place per plans, rebar reinforcement is in place per plans, post tension cabling is installed and properly spaced per plans, plumbing pipes are properly wrapped with foam for protection, underground electrical for kitchen island is installed, and Ufer ground is installed on right side of garage. Okay to pour concrete for footings and slab on grade.
05/06/2024 COT - RSEL - Grounding/Bonding Passed Concrete forms are set, masa clips are spaced properly, shear wall clips are in place per plans, rebar reinforcement is in place per plans, post tension cabling is installed and properly spaced per plans, plumbing pipes are properly wrapped with foam for protection, underground electrical for kitchen island is installed, and Ufer ground is installed on right side of garage. Okay to pour concrete for footings and slab on grade.
05/06/2024 COT - RSBU - Excavation/Rebar/Zoning Passed Concrete forms are set, masa clips are spaced properly, shear wall clips are in place per plans, rebar reinforcement is in place per plans, post tension cabling is installed and properly spaced per plans, plumbing pipes are properly wrapped with foam for protection, underground electrical for kitchen island is installed, and Ufer ground is installed on right side of garage. Okay to pour concrete for footings and slab on grade.
05/17/2024 COT - RSBU - Exterior Clips/Sheathing Passed Exterior wall sheathing is properly installed and secured to the studs per plans and code. Bottom plates are secured to the concrete floor with masa clips or a/b bolts. Shear wall clips are properly secured to studs with nails and all large headers are properly secured with straps and nails. Okay to proceed.
05/17/2024 COT - RSBU - Roof Nailing Passed All trusses are properly secured to top plate with nails and H2.5 clips. All plywood sheathing is properly secured to trusses with nails per plans and code. Okay to proceed.
06/10/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed Mechanical, electrical, and plumbing rough-in is complete. Okay to proceed with installation of insulation and drywall.
06/10/2024 COT - RSPL - Gas Pressure Test Passed Gas line is installed and holding 15# of compressed air. Okay to proceed.
06/10/2024 BULD - Electrical Clearance Passed Electrical panel, breakers, and temporary GFCI outlet are installed. Issuing an ECO Clearance to TEP to energize electrical system.
06/10/2024 RSBU - Building Progress Passed Gas line is installed and holding 15# of compressed air. Okay to proceed. Mechanical, electrical, and plumbing rough-in is complete. Roof dry-in is complete. Foam and lathe for stucco is properly secured to exterior walls.
07/08/2024 COT - RSBU - Interior Shear Bracing Passed
08/22/2024 COT - BULD - SWG Clearance Passed SWG for meter only
08/22/2024 COT - RSEL - Electrical Final Passed
08/22/2024 COT - RSEL - Outdoor Lighting Passed
08/22/2024 COT - RSME - Mechanical Final Passed
08/27/2024 COT - RSPL - Plumbing Final Passed
08/27/2024 ENGR Engineering Final Passed
08/27/2024 RSBU - Building Final Passed

Documents

File Name Document Type  
COFO_FINALCOFO_RESIDENTIAL.PDF DOCUMENTS VIEW
147401 PT LOT 204 COMPLETE-2024-06-27_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
LOT 204 APPLICATION_V1.PDF DOCUMENTS VIEW
LOT 204 PLOT PLAN_V1.PDF DOCUMENTS VIEW
LOT 204 SPECIAL INSPECTION CERTIFICATE-2024-01-05_V1.PDF DOCUMENTS VIEW