Permit: TC-MDP-1223-01903
Permit Details
Status:
Inspections Complete
Type:
Model Building Permit
Address:
3075 N SIBLEY MINE RD
Address NEW:
3075 N SIBLEY MINE RD
Apply Date:
06/04/2024
Applicant:
Description:
SFR K35D T21-M0032
Permit Reviews
Permit Number - TC-MDP-1223-01903
Permit Status: Inspections complete
Permit Description: SFR K35D T21-M0032
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/04/2024 | SITE FROM MODEL PERMIT - SUBDIVISION v.1 | 06/05/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-1223-01903
Permit Status: Inspections complete
Permit Description: SFR K35D T21-M0032
Total Outstanding Activity Conditions - 3
| Date | Name |
|---|---|
| 06/05/2024 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
| 06/05/2024 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
| 06/05/2024 | Post-Tension Inspection Report is required. |
Conditions
Permit Number - TC-MDP-1223-01903
Permit Status: Inspections complete
Permit Description: SFR K35D T21-M0032
| Date | Description | Comments |
|---|---|---|
| 12/15/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
| 06/05/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. | |
| 08/08/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-1223-01903
Permite Description: SFR K35D T21-M0032
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/15/2024 | COT - RSEL - Grounding/Bonding | N/A | Partial Pass | |
| 09/04/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | 9/3/24: fire blocking required at garage by main panel, exterior light fixture is exciting box fill at garage, electrical conduit at kitchen outside of wall, secondary drain must be properly sloped. STOPPED INSPECTION MORE ITEMS MAY BE ADDED 9/4/24: seal all penetrations through vapor barrier, circuits tied in at bedroom and hallway, smoke detector must be 3' from bathroom opening, thermostat shall be no higher than 54" above finish floor, |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-1223-01903
Permit Description: SFR K35D T21-M0032
Total Completed Inspections - 21
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/03/2024 | COT - RSPL - Yard Water Line | Passed | 7/3/24: MWL under air pressure test ok to backfill. Shading required | |
| 07/09/2024 | COT - RSPL - Sewer | Passed | 7/3/24: not ready 7/5/24: test stack must be 5' in height. Must be filled completely. 7/9/24: corrections made ok to backfill. Shading required |
|
| 07/09/2024 | COT - RSPL - Rough Soil | Passed | 7/3/24: not ready 7/5/24: test stack must be 5' in height. Must be filled completely. 7/9/24: corrections made ok to backfill. Shading required |
|
| 07/15/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
| 07/15/2024 | COT - RSBU - Preslab | Passed | ||
| 07/15/2024 | COT - RSEL - Electrical Underground | Passed | ||
| 08/06/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | ||
| 08/06/2024 | COT - RSBU - Roof Nailing | Passed | ||
| 09/03/2024 | COT - RSEL - Grounding/Bonding | Passed | ||
| 09/03/2024 | COT - RSPL - Gas Pressure Test | Passed | ||
| 09/05/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 9/3/24: fire blocking required at garage by main panel, exterior light fixture is exciting box fill at garage, electrical conduit at kitchen outside of wall, secondary drain must be properly sloped. STOPPED INSPECTION MORE ITEMS MAY BE ADDED 9/4/24: seal all penetrations through vapor barrier, circuits tied in at bedroom and hallway, smoke detector must be 3' from bathroom opening, thermostat shall be no higher than 54" above finish floor, 9/5/24: corrections made. |
|
| 09/05/2024 | BULD - Electrical Clearance | Passed | 9/5/24: ECO TEP clearance | |
| 09/17/2024 | COT - RSBU - Interior Shear Bracing | Passed | ||
| 10/30/2024 | COT - BULD - SWG Clearance | Passed | ||
| 11/18/2024 | COT - RSEL - Electrical Final | Passed | ||
| 11/18/2024 | COT - RSEL - Outdoor Lighting | Passed | ||
| 11/18/2024 | COT - RSME - Mechanical Final | Passed | ||
| 11/18/2024 | COT - RSPL - Plumbing Final | Passed | ||
| 11/18/2024 | ENGR Engineering Final | Passed | ||
| 11/18/2024 | RSBU - Building Final | Passed | ||
| 11/18/2024 | RSBU - Building Progress | Passed |