Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections Complete
Type:
Model Building Permit
Address NEW:
972 W SILVERLAKE RD
Apply Date:
11/14/2023
Applicant:
Jose Quintero
Description:
SWDUPLEXM SUNSET MODEL DUPLEX 3-2 TRUSS REVIEW COMPLETE PREVIOUSLY APPROVED MODEL T20-00004

Permit Reviews

Permit Number - TC-MDP-1123-01792
Permit Status: Inspections complete
Permit Description: SWDUPLEXM SUNSET MODEL DUPLEX 3-2 TRUSS REVIEW COMPLETE PREVIOUSLY APPROVED MODEL T20-00004
Start Date Submittal Complete Date Status  
11/14/2023 SITE FROM MODEL PERMIT - SUBDIVISION v.1 11/15/2023 APPROVED Review Details

Conditions

Permit Number - TC-MDP-1123-01792
Permit Status: Inspections complete
Permit Description: SWDUPLEXM SUNSET MODEL DUPLEX 3-2 TRUSS REVIEW COMPLETE PREVIOUSLY APPROVED MODEL T20-00004
Date Description Comments
11/15/2023 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact.
06/14/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.

Outstanding Inspections

Permit Status: Inspections Complete
Permit Number: TC-MDP-1123-01792
Permite Description: SWDUPLEXM SUNSET MODEL DUPLEX 3-2 TRUSS REVIEW COMPLETE PREVIOUSLY APPROVED MODEL T20-00004
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
12/22/2023 COT - RSEL - Electrical Underground N/A Not Applicable
04/12/2024 COT - RSPL - Gas Pressure Test N/A Not Applicable
04/12/2024 COT - BULD - SWG Clearance N/A Not Applicable

Completed Inspections

Permit Status: Inspections Complete
Permit Number: TC-MDP-1123-01792
Permit Description: SWDUPLEXM SUNSET MODEL DUPLEX 3-2 TRUSS REVIEW COMPLETE PREVIOUSLY APPROVED MODEL T20-00004
Total Completed Inspections - 19
Date Description Inspector Results Comments
12/06/2023 COT - RSPL - Rough Soil Passed Approved. Okay to backfill. Shading required. 12/6/2023
12/08/2023 COT - RSBU - Preslab Passed Ok to place concrete.
12/14/2023 COT - RSEL - Grounding/Bonding Passed Footings and slab have been poured..placed at contractor’s risk.
12/14/2023 COT - RSBU - Excavation/Rebar/Zoning Passed Footings and slab have been poured…contractor placed at own risk.
12/18/2023 COT - RSBU - Roof Nailing Passed
12/18/2023 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed
12/19/2023 COT - RSBU - Firewall/Fire Barrier/Firestop Passed
12/22/2023 BULD - Electrical Clearance Passed 12/22/23: ECO TEP CLEARANCE for 972 W Silverlake RD unit 1 and unit 2
12/22/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed
01/26/2024 COT - RSPL - Yard Water Line Passed Okay to backfill shading required. 1/26/24
04/10/2024 COT - RSPL - Sewer Passed Two,four inch sewer lines from site to,main,sewer in roadway. Covered, compacted and asphalted.
04/12/2024 ENGR Engineering Final Passed
04/12/2024 RSBU - Building Progress Passed
04/12/2024 COT - RSBU - Interior Shear Bracing Passed
04/18/2024 COT - RSEL - Outdoor Lighting Passed
04/19/2024 COT - RSEL - Electrical Final Passed 4/18/24: weep screed clearance must be 4" above grade (not meeting clearance throughout), water heater T&P drain must terminate 6" above grade, water heaters missing pan per code P2801.6 and pan shall drain no less than 6" above grade, A/C condensate drain must be UV coated, Arc-fault breakers required at kitchen circuits and laundry circuit. Cut clean outs to grade.
4/19/24: corrections made.
04/19/2024 COT - RSME - Mechanical Final Passed 4/18/24: weep screed clearance must be 4" above grade (not meeting clearance throughout), water heater T&P drain must terminate 6" above grade, water heaters missing pan per code P2801.6 and pan shall drain no less than 6" above grade, A/C condensate drain must be UV coated, Arc-fault breakers required at kitchen circuits and laundry circuit. Cut clean outs to grade.
4/19/24: corrections made.
04/19/2024 COT - RSPL - Plumbing Final Passed 4/18/24: weep screed clearance must be 4" above grade (not meeting clearance throughout), water heater T&P drain must terminate 6" above grade, water heaters missing pan per code P2801.6 and pan shall drain no less than 6" above grade, A/C condensate drain must be UV coated, Arc-fault breakers required at kitchen circuits and laundry circuit. Cut clean outs to grade.
4/19/24: corrections made.
04/19/2024 RSBU - Building Final Passed 4/18/24: weep screed clearance must be 4" above grade (not meeting clearance throughout), water heater T&P drain must terminate 6" above grade, water heaters missing pan per code P2801.6 and pan shall drain no less than 6" above grade, A/C condensate drain must be UV coated, Arc-fault breakers required at kitchen circuits and laundry circuit. Cut clean outs to grade.
4/19/24: corrections made.

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
972 W SILVERLAKE RD SITEPLAN 11-14-23_V1.PDF DOCUMENTS VIEW