Inspection History Details
Inspection Status: Not Ready
Inspection History: COT - RSME - Mechanical Final
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/12/2024 | COT - RSME - Mechanical Final | Not Ready | ||
| 04/18/2024 | COT - RSME - Mechanical Final | Re-inspection required | 4/18/24: weep screed clearance must be 4" above grade (not meeting clearance throughout), water heater T&P drain must terminate 6" above grade, water heaters missing pan per code P2801.6 and pan shall drain no less than 6" above grade, A/C condensate drain must be UV coated, Arc-fault breakers required at kitchen circuits and laundry circuit. Cut clean outs to grade. | |
| 04/19/2024 | COT - RSME - Mechanical Final | Passed | 4/18/24: weep screed clearance must be 4" above grade (not meeting clearance throughout), water heater T&P drain must terminate 6" above grade, water heaters missing pan per code P2801.6 and pan shall drain no less than 6" above grade, A/C condensate drain must be UV coated, Arc-fault breakers required at kitchen circuits and laundry circuit. Cut clean outs to grade. 4/19/24: corrections made. |