Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-MDP-1123-01719
Permit Details
Status:
Inspections Complete
Type:
Model Building Permit
Address:
9708 E GRAY HAWK DR
Address NEW:
9708 E GRAY HAWK DR
Apply Date:
11/01/2023
Applicant:
Helen Ormsby
Description:
Casas del Cerrito H35B Model Plan
Permit Reviews
Permit Number - TC-MDP-1123-01719
Permit Status: Inspections complete
Permit Description: Casas del Cerrito H35B Model Plan
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/30/2025 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 02/03/2025 | REQUIRES RESUBMIT |
| 02/06/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.2 | 02/13/2024 | APPROVED |
| 05/23/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 05/29/2024 | APPROVED |
| 02/11/2025 | BUILDING DEFERRED SUBMITTAL REVIEW v.2 | 02/13/2025 | APPROVED |
| 11/03/2023 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 11/13/2023 | REQUIRES RESUBMIT |
Outstanding Activity Conditions
Permit Number - TC-MDP-1123-01719
Permit Status: Inspections complete
Permit Description: Casas del Cerrito H35B Model Plan
Total Outstanding Activity Conditions - 2
| Date | Name |
|---|---|
| 05/28/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
| 10/18/2023 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. |
Conditions
Permit Number - TC-MDP-1123-01719
Permit Status: Inspections complete
Permit Description: Casas del Cerrito H35B Model Plan
| Date | Description | Comments |
|---|---|---|
| 11/03/2023 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. | |
| 11/03/2023 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. | |
| 11/13/2023 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. | |
| 11/13/2023 | Post-Tension Inspection Report is required. | |
| 05/28/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
| 10/18/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
| 11/03/2023 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. | |
| 11/13/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-1123-01719
Permite Description: Casas del Cerrito H35B Model Plan
Total Outstanding Inspections - 4
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/20/2024 | COT - RSPL - Sewer | N/A | Canceled | 11/20/24: Cancelled by Jorge Teran, underground not complete and not under water pressure test. |
| 11/20/2024 | COT - RSPL - Rough Soil | N/A | Canceled | 11/20/24: Cancelled by Jorge Teran, underground not complete and not under water pressure test. |
| 11/20/2024 | COT - RSPL - Backwater Valve | N/A | Canceled | 11/20/24: Cancelled by Jorge Teran, underground not complete and not under water pressure test. |
| 01/06/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | 01/06/25 1. Replace drywall screws on fan mounts throughout. 2. Strap HVAC refrigerant lines above ceiling every 6ft. 3. Nail plates needed throughout. 4. Master bedroom east wall 2x4 in notched more than 40%, needs a stud shoe or sister stud. 5. Flex duct feeding hallway bathroom needs to be supported. 6. Hallway circuit by entry door is tied into bedroom circuits, needs to be on circuit 20 per plan. 7. Seal hole in top plate in master bedroom east wall. |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-1123-01719
Permit Description: Casas del Cerrito H35B Model Plan
Total Completed Inspections - 22
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/20/2024 | COT - RSPL - Yard Water Line | Passed | 11/20/24: Main water line is connected to the City water supply system and under street pressure. Okay to shade pipe and backfill trench. | |
| 11/21/2024 | COT - RSEL - Grounding/Bonding | Passed | Under ground plumbing approved. Two ground rods in place for UFER attachment. Okay to backfill. Shading required. 11/21/2024 | |
| 11/25/2024 | COT - RSPL - Sewer | Passed | 11/25/24: Underground plumbing is connected to main sewer line and under water pressure test. Okay to shade pipe and backfill trench. | |
| 11/25/2024 | COT - RSPL - Rough Soil | Passed | 11/25/24: Underground plumbing is connected to main sewer line and under water pressure test. Okay to shade pipe and backfill trench. | |
| 12/02/2024 | BULD - Electrical Clearance | Passed | 12-2-24, panel approved to be energized. ECO clearance issued to TEP. | |
| 12/02/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | 12-2-24, excavation/setbacks verified as per approved plans. Okay to pour concrete. | |
| 12/02/2024 | COT - RSBU - Preslab | Passed | 12-2-24, preslab approved. Okay to pour concrete. | |
| 12/02/2024 | COT - RSEL - Electrical Underground | Passed | 12-2-24, conduit is installed for kitchen island. Okay to pour concrete. | |
| 12/02/2024 | COT - RSPL - Backwater Valve | Passed | 12-2-24, backwater valve previously inspected and verified on 11-20-24. | |
| 12/13/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 12/13/24 passed after corrections were made while onsite. | |
| 12/13/2024 | COT - RSBU - Roof Nailing | Passed | 12/13/24 pass | |
| 01/06/2025 | COT - RSPL - Gas Pressure Test | Passed | ||
| 01/07/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 1/7/25 corrections made | |
| 01/15/2025 | COT - RSBU - Interior Shear Bracing | Passed | Drywall for interior shear walls is properly secured to studs per plan requirements of 4 & 12. Okay to proceed with tape, texture, and painting of walls and ceiling. | |
| 02/27/2025 | COT - BULD - SWG Clearance | Passed | 2-27-25, SWG clearance inspection approved pending City. Okay for SWG to install service-Clearance issued. | |
| 02/27/2025 | COT - RSEL - Electrical Final | Passed | 2-27-25, mechanical, electrical, outdoor lighting, plumbing and building final approved pending. | |
| 02/27/2025 | COT - RSEL - Outdoor Lighting | Passed | 2-27-25, mechanical, electrical, outdoor lighting, plumbing and building final approved pending. | |
| 02/27/2025 | COT - RSME - Mechanical Final | Passed | 2-27-25, mechanical, electrical, outdoor lighting, plumbing and building final approved pending. | |
| 02/27/2025 | COT - RSPL - Plumbing Final | Passed | 2-27-25, mechanical, electrical, outdoor lighting, plumbing and building final approved pending. | |
| 02/27/2025 | RSBU - Building Final | Passed | 2-27-25, mechanical, electrical, outdoor lighting, plumbing and building final approved pending. | |
| 02/28/2025 | ENGR Engineering Final | Passed | ||
| 09/19/2025 | RSBU - Building Progress | Passed |