Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections Complete
Type:
Model Building Permit
Address NEW:
5998 E BENBURB LN
Apply Date:
10/28/2025
Applicant:
David Alcantar III
Description:
Blackhawk L019 Archer (Model Master Plan TC-MDP-1025-00678)

Permit Reviews

Permit Number - TC-MDP-1025-00701
Permit Status: Inspections complete
Permit Description: Blackhawk L019 Archer (Model Master Plan TC-MDP-1025-00678)
Start Date Submittal Complete Date Status  
12/08/2025 SITE FROM MODEL PERMIT - SUBDIVISION v.2 12/15/2025 APPROVED Review Details
12/15/2025 RESTAMP - RESIDENTIAL v.1 12/16/2025 APPROVED Review Details
11/25/2025 SITE FROM MODEL PERMIT - SUBDIVISION v.1 12/04/2025 REQUIRES RESUBMIT Review Details

Outstanding Activity Conditions

Permit Number - TC-MDP-1025-00701
Permit Status: Inspections complete
Permit Description: Blackhawk L019 Archer (Model Master Plan TC-MDP-1025-00678)
Total Outstanding Activity Conditions - 5
Date Name
10/29/2025 Submit the Air Leakage & Duct Tightness Test Report completed by an Approved Special Inspector prior to Final Inspections.
10/29/2025 Post-Tension Inspection Report is required.
10/29/2025 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/
11/25/2025 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
11/25/2025 SPECIAL INSPECTION FOR SITE PREPARATION IS REQUIRED.

Conditions

Permit Number - TC-MDP-1025-00701
Permit Status: Inspections complete
Permit Description: Blackhawk L019 Archer (Model Master Plan TC-MDP-1025-00678)
Date Description Comments
10/29/2025 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.
10/29/2025 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Inspections Complete
Permit Number: TC-MDP-1025-00701
Permite Description: Blackhawk L019 Archer (Model Master Plan TC-MDP-1025-00678)
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
01/23/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Re-inspection required 01/23/2026
Add anchor bolts at marked locations for arms up between masa clips or exceeding 12" from plate edge, add shot pins at marked locations for interior bottom plate edges.

Completed Inspections

Permit Status: Inspections Complete
Permit Number: TC-MDP-1025-00701
Permit Description: Blackhawk L019 Archer (Model Master Plan TC-MDP-1025-00678)
Total Completed Inspections - 20
Date Description Inspector Results Comments
01/12/2026 COT - RSPL - Yard Water Line Passed 01/12/2026
Holding under test to meter with blue tracer - ok to backfill with shading materials.
01/12/2026 COT - RSPL - Sewer Passed 01/12/2026
Holding under test to HCS with green tracer wire - ok to backfill with shading materials.
01/12/2026 COT - RSPL - Rough Soil Passed 01/12/2026
All fixtures present & under test - ok to backfill with shading materials.
01/16/2026 COT - RSBU - Preslab Passed 01/16/2026
Approved per site plan, setbacks verified and Ufer in place - ok for concrete placement.
01/16/2026 COT - RSEL - Electrical Underground Passed
01/16/2026 COT - RSBU - Excavation/Rebar/Zoning Passed 01/16/2026
Approved per site plan, setbacks verified and Ufer in place.
01/23/2026 COT - RSBU - Roof Nailing Passed 01/23/2026
Approved per plan, verified truss calc and roof panels.
02/03/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed Approved. Corrections were made. 2/3/2026
02/13/2026 BULD - Electrical Clearance Passed 2/13/26: TEP ECO CLEARANCE FOR 5998 E BENBURB LN
02/17/2026 COT - RSPL - Gas Pressure Test Passed 2.17.26
Approved
02/17/2026 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 2.17.26
Approved
02/17/2026 RSBU - Building Progress Passed
02/25/2026 COT - RSBU - Interior Shear Bracing Passed
03/27/2026 COT - BULD - SWG Clearance Passed 3.27.26
Approved for SWG clearance
04/03/2026 COT - RSEL - Outdoor Lighting Passed
04/03/2026 COT - RSME - Mechanical Final Passed 4.3.26
approved
04/03/2026 COT - RSPL - Plumbing Final Passed 4.3.26
approved
04/03/2026 ENGR Engineering Final Passed
04/08/2026 COT - RSEL - Electrical Final Passed 04/08/2026
Correction made to prior inspection.
04/08/2026 RSBU - Building Final Passed 04/08/2026
Correction made to prior inspection.

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
BH 212_V2.PDF DOCUMENTS VIEW
BH 212 LETTER_V1.PDF DOCUMENTS VIEW