Permit: TC-MDP-1025-00625
Permit Details
Status:
Inspections Complete
Type:
Model Building Permit
Address:
6232 S SPRUCE GOOSE AV
Address NEW:
6232 S SPRUCE GOOSE AV
Apply Date:
03/05/2026
Applicant:
Celina Rodriguez
Description:
Cielo Reserve 1383 SFR (Model master plan TC-MDP-0525-00298)
Permit Reviews
Permit Number - TC-MDP-1025-00625
Permit Status: Inspections complete
Permit Description: Cielo Reserve 1383 SFR (Model master plan TC-MDP-0525-00298)
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 03/11/2026 | SITE FROM MODEL PERMIT - SUBDIVISION v.1 | 03/18/2026 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-1025-00625
Permit Status: Inspections complete
Permit Description: Cielo Reserve 1383 SFR (Model master plan TC-MDP-0525-00298)
Total Outstanding Activity Conditions - 4
| Date | Name |
|---|---|
| 03/16/2026 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
| 03/16/2026 | SPECIAL INSPECTION FOR SITE PREPARATION IS REQUIRED. |
| 10/02/2025 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
| 10/02/2025 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/ |
Conditions
Permit Number - TC-MDP-1025-00625
Permit Status: Inspections complete
Permit Description: Cielo Reserve 1383 SFR (Model master plan TC-MDP-0525-00298)
| Date | Description | Comments |
|---|---|---|
| 10/02/2025 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-1025-00625
Permite Description: Cielo Reserve 1383 SFR (Model master plan TC-MDP-0525-00298)
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/13/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Not Ready | 04/13/2026 Not ready, trades still working at time of inspection. |
| 04/14/2026 | COT - RSBU - Roof Nailing | N/A | Re-inspection required | 04/14/2026 Add washer plates to anchor bolt at SW11 in front garage, add nails to SW11 where over-penetration occurs in rear wall, add strap to interior SW11 near garage to secure shear to top plates as marked, missing run of nails to top plate every 4" o.c. on SW11 at north wall, add shot pins as marked on interior wall sill plates. Truss A2 in great room as marked requires engineer fix/letter, add (6) H2.5 clips from A3 trusses to top plate at 3rd bearing point. |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-1025-00625
Permit Description: Cielo Reserve 1383 SFR (Model master plan TC-MDP-0525-00298)
Total Completed Inspections - 20