Inspection History Details
Inspection Status: Not Ready
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/13/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Not Ready | 04/13/2026 Not ready, trades still working at time of inspection. |
|
| 04/14/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 04/14/2026 Add washer plates to anchor bolt at SW11 in front garage, add nails to SW11 where over-penetration occurs in rear wall, add strap to interior SW11 near garage to secure shear to top plates as marked, missing run of nails to top plate every 4" o.c. on SW11 at north wall, add shot pins as marked on interior wall sill plates. Truss A2 in great room as marked requires engineer fix/letter, add (6) H2.5 clips from A3 trusses to top plate at 3rd bearing point. |
|
| 04/15/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 04/15/2026 All corrections made to prior inspection. |