Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Issued
Type:
Model Building Permit
Apply Date:
10/23/2024
Applicant:
Mark Alteri
Description:
PV 2378SFR

Permit Reviews

Permit Number - TC-MDP-1024-01241
Permit Status: Issued
Permit Description: PV 2378SFR
Start Date Submittal Complete Date Status  
10/28/2024 SITE FROM MODEL PERMIT - PRODUCTION v.1 11/14/2024 APPROVED Review Details
12/18/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 12/18/2024 APPROVED Review Details
01/16/2025 BUILDING DEFERRED SUBMITTAL REVIEW v.1 01/17/2025 APPROVED Review Details

Conditions

Permit Number - TC-MDP-1024-01241
Permit Status: Issued
Permit Description: PV 2378SFR
Date Description Comments
10/23/2024 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.
10/30/2024 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
10/23/2024 Post-Tension Inspection Report is required.
10/23/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.
10/23/2024 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/
10/30/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Issued
Permit Number: TC-MDP-1024-01241
Permite Description: PV 2378SFR
Total Outstanding Inspections - 8
Last Inspection Date Description Inspector Results Comments
12/19/2024 COT - RSPL - Yard Water Line N/A Partial Pass 11/22:24 corrections a were made. Pass
12/02/2024 COT - RSEL - Grounding/Bonding N/A Partial Pass
12/03/2024 COT - RSBU - Excavation/Rebar/Zoning N/A Re-inspection required Partial pass. Pending interior footing for holdown hdu11 per detail sd1(8). Pending exterior footings per plan. 12/2/2024
12/3/24: multiple interior holdowns missing per plan. Per previous notes.
12/03/2024 COT - RSBU - Preslab N/A Re-inspection required Partial pass. Pending interior footing for holdown hdu11 per detail sd1(8). Pending exterior footings per plan. 12/2/2024
12/3/24: multiple interior holdowns missing per plan. Per previous notes.
01/15/2025 COT - RSBU - Roof Nailing N/A Re-inspection required 1-15-25, shear wall #7 has over penetrated nails throughout together with nailing not per approved plans ( edges call for 3" o.c. and was measured at 4" o.c.), exterior sheathing nailing around home has over penetrated nailing(exceeding 1/8"max allowable nailing depth),missing cs16 strap on south exterior wall near back patio, htt4 at garage shear wall missing nuts, add anchor bolts to marked areas at garage together with missing anchor bolt & washer/nut for shear wall #5 at stairs.STOPPED INSPECTION-ADDITIONAL ITEMS MAY BE NOTED.
01/15/2025 COT - RSBU - Exterior Clips/Sheathing N/A Re-inspection required 1-15-25, shear wall #7 has over penetrated nails throughout together with nailing not per approved plans ( edges call for 3" o.c. and was measured at 4" o.c.), exterior sheathing nailing around home has over penetrated nailing(exceeding 1/8"max allowable nailing depth),missing cs16 strap on south exterior wall near back patio, htt4 at garage shear wall missing nuts, add anchor bolts to marked areas at garage together with missing anchor bolt & washer/nut for shear wall #5 at stairs.STOPPED INSPECTION-ADDITIONAL ITEMS MAY BE NOTED.
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Scheduled
COT - RSPL - Gas Pressure Test N/A Scheduled

Completed Inspections

Permit Status: Issued
Permit Number: TC-MDP-1024-01241
Permit Description: PV 2378SFR
Total Completed Inspections - 7
Date Description Inspector Results Comments
11/21/2024 COT - RSPL - Rough Soil Passed
11/21/2024 COT - RSPL - Sewer Passed
12/03/2024 COT - RSEL - Electrical Underground Passed Conduit not in place. 12/2/2024
12/3/24: corrections made.
01/21/2025 COT - RSBU - Roof Nailing Passed
01/21/2025 COT - RSBU - Exterior Clips/Sheathing Passed
02/13/2025 COT - RSBU - Firewall/Fire Barrier/Firestop Passed 2/13/25 pass
02/13/2025 RSBU - Building Progress Passed

Scheduled Inspections

Scheduled Inspections - TC-MDP-1024-01241
Status: Issued
Description: PV 2378SFR

Documents

File Name Document Type  
151968 PT LOT 3 COMPLETE-2025-01-09_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
PRL 3 PP FOR SUBMITTAL_V1.PDF DOCUMENTS VIEW
PRL 3 PT CERT-2024-10-23_V1.PDF DOCUMENTS VIEW