Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Roof Nailing 

Permit Number - TC-MDP-1024-01241

Inspection Description - COT - RSBU - Roof Nailing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
01/15/2025 COT - RSBU - Roof Nailing  Re-inspection required 1-15-25, shear wall #7 has over penetrated nails throughout together with nailing not per approved plans ( edges call for 3" o.c. and was measured at 4" o.c.), exterior sheathing nailing around home has over penetrated nailing(exceeding 1/8"max allowable nailing depth),missing cs16 strap on south exterior wall near back patio, htt4 at garage shear wall missing nuts, add anchor bolts to marked areas at garage together with missing anchor bolt & washer/nut for shear wall #5 at stairs.STOPPED INSPECTION-ADDITIONAL ITEMS MAY BE NOTED.
01/21/2025 COT - RSBU - Roof Nailing  Passed