Start Date Submittal Complete Date Status  
11/15/2024 SITE FROM MODEL PERMIT - PRODUCTION v.1 12/05/2024 APPROVED Review Details
11/06/2025 BUILDING DEFERRED SUBMITTAL REVIEW v.1 11/07/2025 APPROVED Review Details

Conditions

Permit Number - TC-MDP-1024-01237
Permit Status: Complete
Permit Description: SFR MERI213021 T21-M0065 (Model master plan TC-MDP-0223-00546)
Date Description Comments
10/21/2024 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.
11/18/2024 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
11/18/2024 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
11/18/2024 Post-Tension Inspection Report is required.
10/21/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.
10/21/2024 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/
11/18/2024 SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED.
11/18/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-MDP-1024-01237
Permite Description: SFR MERI213021 T21-M0065 (Model master plan TC-MDP-0223-00546)
Total Outstanding Inspections - 4
Last Inspection Date Description Inspector Results Comments
09/23/2025 COT - RSBU - Preslab N/A Re-inspection required 9-23-25: reinforcement at garage hold-downs are lying on ground-provide proper attachment & clearance. Clean out footings at garage & at back porch areas-see plans for footing depths at mentioned locations & Compact pad at kitchen conduit areas.
09/23/2025 COT - RSBU - Excavation/Rebar/Zoning N/A Re-inspection required 9-23-25: reinforcement at garage hold-downs are lying on ground-provide proper attachment & clearance. Clean out footings at garage & at back porch areas-see plans for footing depths at mentioned locations & Compact pad at kitchen conduit areas.
10/27/2025 COT - RSBU - Interior Shear Bracing N/A Re-inspection required 10-27-25: per table R702.3.5 of the 2018 IRC nails for 1/2" drywall at non shear walls can be spaced along edges no greater than 8" o.c... add nails along the base throughout on both levels and schedule a reinspected when ready.
09/23/2025 COT - RSEL - Grounding/Bonding N/A Partial Pass 9-23-25: partial pass for ufer only.

Completed Inspections

Permit Status: Complete
Permit Number: TC-MDP-1024-01237
Permit Description: SFR MERI213021 T21-M0065 (Model master plan TC-MDP-0223-00546)
Total Completed Inspections - 21
Date Description Inspector Results Comments
09/17/2025 COT - RSPL - Sewer Passed
09/17/2025 COT - RSPL - Yard Water Line Passed 9.17.2025
Verified water under test. Ensure large rocks and debris cleared. Okay to backfill, shading required.
09/17/2025 COT - RSPL - Rough Soil Passed 9.17.2025
Verified plumping per plan and under test. Ensure large rocks and debris cleared. Okay to backfilling, shading required.
09/23/2025 COT - RSEL - Electrical Underground Passed 9-23-25: approved.
09/24/2025 COT - RSBU - Preslab Passed
09/24/2025 COT - RSBU - Excavation/Rebar/Zoning Passed
10/03/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed
10/03/2025 COT - RSBU - Roof Nailing Passed
10/16/2025 COT - RSPL - Gas Pressure Test Passed 10-16-25: gas pressure test approved. Verified at 15 psi.
10/16/2025 BULD - Electrical Clearance Passed 10-16-25: okay to energize panel. ECO clearance issued to TEP.
10/17/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 10.17.25
Corrected, proceed
10/28/2025 COT - RSBU - Interior Shear Bracing Passed 10.28.2025
Corrections made from yesterday's inspection.
11/26/2025 COT - BULD - SWG Clearance Passed 11-26-25: okay to meter-SWG clearance issued.
12/03/2025 COT - RSEL - Electrical Final Passed 12.3.25
Approved
12/03/2025 COT - RSEL - Grounding/Bonding Passed 12.3.25
Approved
12/03/2025 COT - RSEL - Outdoor Lighting Passed 12.3.25
Approved
12/03/2025 COT - RSME - Mechanical Final Passed 12.3.25
Approved
12/03/2025 COT - RSPL - Plumbing Final Passed 12.3.25
Approved
12/03/2025 ENGR Engineering Final Passed Site is complete in accordance with approved plans.
12/03/2025 RSBU - Building Final Passed 12.3.25
Approved
12/03/2025 RSBU - Building Progress Passed 12.3.25
Approved

Documents

File Name Document Type  
COFO_FINALCOFO_RESIDENTIAL (SSRS).PDF DOCUMENTS VIEW
241720- VALENCIA CROSSING- LOT 121- PT-2025-11-04_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
LOT 121 PLOT PLAN_V1.PDF DOCUMENTS VIEW
LOT 121 SPECIAL INSPECTION CERTIFICATE-2024-11-08_V1.PDF DOCUMENTS VIEW