Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Model Building Permit
Address:
7451 S KELLER LN
Apply Date:
10/24/2023
Applicant:
Joshua Swinney
Description:
Great Sand Dunes SFR Model Escalara

Permit Reviews

Permit Number - TC-MDP-1023-01704
Permit Status: Complete
Permit Description: Great Sand Dunes SFR Model Escalara
Start Date Submittal Complete Date Status  
11/15/2023 SITE FROM MODEL PERMIT - PRODUCTION v.1 11/21/2023 APPROVED Review Details
08/22/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 08/23/2024 APPROVED Review Details

Conditions

Permit Number - TC-MDP-1023-01704
Permit Status: Complete
Permit Description: Great Sand Dunes SFR Model Escalara
Date Description Comments
11/15/2023 Please contact Pima County Addressing to resolve issue. Addressing@pima.gov or 520-724-9512
11/28/2023 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit https://www.tucsonaz.gov/files/sharedassets/public/v/1/pdsd/documents/permits/residential-permits/pdsd_owner_builder_affidavit_081623.pdf, is required prior to issuance of permit. Contractor or Owner must have a TDC Online account and be added to the permit as a contact. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.
04/04/2024 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
01/20/2023 Post-Tension Inspection Report is required.
04/04/2024 Post-Tension Inspection Report is required.
03/21/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
11/28/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
12/12/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
04/04/2024 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.
12/12/2023 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.
01/20/2023 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.
04/04/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-MDP-1023-01704
Permite Description: Great Sand Dunes SFR Model Escalara
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
03/14/2024 COT - RSBU - Excavation/Rebar/Zoning N/A Partial Pass Setbacks
06/03/2024 COT - BULD - SWG Clearance N/A Not Applicable
06/03/2024 COT - RSPL - Gas Pressure Test N/A Not Applicable

Completed Inspections

Permit Status: Complete
Permit Number: TC-MDP-1023-01704
Permit Description: Great Sand Dunes SFR Model Escalara
Total Completed Inspections - 19
Date Description Inspector Results Comments
03/14/2024 COT - RSPL - Rough Soil Passed
03/28/2024 COT - RSEL - Electrical Underground Passed
04/04/2024 COT - RSBU - Excavation/Rebar/Zoning Passed Concrete forms are set, post tension cabling is properly installed per plans, Simpson clips are properly installed and secured to form work per plans, all plumbing pipes are properly wrapped with foam padding, and 20' rebar is placed in footing for Ufer ground. Okay to pour concrete.
04/04/2024 COT - RSBU - Preslab Passed Concrete forms are set, post tension cabling is properly installed per plans, Simpson clips are properly installed and secured to form work per plans, all plumbing pipes are properly wrapped with foam padding, and 20' rebar is placed in footing for Ufer ground. Okay to pour concrete.
04/04/2024 COT - RSEL - Grounding/Bonding Passed Concrete forms are set, post tension cabling is properly installed per plans, Simpson clips are properly installed and secured to form work per plans, all plumbing pipes are properly wrapped with foam padding, and 20' rebar is placed in footing for Ufer ground. Okay to pour concrete.
04/19/2024 COT - RSBU - Exterior Clips/Sheathing Passed All exterior walls are properly secured to concrete floor with bolts or by hilti nail gun. All shear wall have the proper Hilti brackets in place and are properly secured to the floor with bolts. All exterior shear walls are properly covered with plywood and nailed off per plans. Okay to proceed with window and door installation.
04/19/2024 COT - RSBU - Roof Nailing Passed H2.5 clips are properly attached to each truss and floor joists. Plywood sheathing is properly nailed off on roof and porches. Okay to proceed with roof dry-in.
06/03/2024 COT - RSPL - Yard Water Line Passed
06/05/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 6/4/24: Exhaust fan in bathroom is properly wired, shower pan upstairs is under water test, blocking has been added between floors for upstairs girder beam. Okay to proceed with drywall and insulation installation.
06/17/2024 COT - RSBU - Interior Shear Bracing Passed Interior shear walls are properly drywalled with the correct screw pattern per plan. Okay to proceed with tape, texture, and paint of walls and ceiling.
07/22/2024 BULD - Electrical Clearance Passed Clearance for TEP ECO. 7/22/2024
08/06/2024 COT - RSPL - Sewer Passed
08/27/2024 ENGR Engineering Final Passed
08/30/2024 COT - RSEL - Electrical Final Passed Construction is completed. Mechanical, electrical, and plumbing fixtures are installed and operational. Electrical panel is properly labeled with AFCI/GFCI breakers installed as required. Outdoor lighting is installed per plans and city regulations. Okay to issue Certificate of Occupancy for this project.
08/30/2024 COT - RSEL - Outdoor Lighting Passed Construction is completed. Mechanical, electrical, and plumbing fixtures are installed and operational. Electrical panel is properly labeled with AFCI/GFCI breakers installed as required. Outdoor lighting is installed per plans and city regulations. Okay to issue Certificate of Occupancy for this project.
08/30/2024 COT - RSME - Mechanical Final Passed Construction is completed. Mechanical, electrical, and plumbing fixtures are installed and operational. Electrical panel is properly labeled with AFCI/GFCI breakers installed as required. Outdoor lighting is installed per plans and city regulations. Okay to issue Certificate of Occupancy for this project.
08/30/2024 COT - RSPL - Plumbing Final Passed Construction is completed. Mechanical, electrical, and plumbing fixtures are installed and operational. Electrical panel is properly labeled with AFCI/GFCI breakers installed as required. Outdoor lighting is installed per plans and city regulations. Okay to issue Certificate of Occupancy for this project.
08/30/2024 RSBU - Building Final Passed Construction is completed. Mechanical, electrical, and plumbing fixtures are installed and operational. Electrical panel is properly labeled with AFCI/GFCI breakers installed as required. Outdoor lighting is installed per plans and city regulations. Okay to issue Certificate of Occupancy for this project.
08/30/2024 RSBU - Building Progress Passed Construction is completed. Mechanical, electrical, and plumbing fixtures are installed and operational. Electrical panel is properly labeled with AFCI/GFCI breakers installed as required. Outdoor lighting is installed per plans and city regulations. Okay to issue Certificate of Occupancy for this project.

Documents

File Name Document Type  
COFO_FINALCOFO_RESIDENTIAL.PDF DOCUMENTS VIEW
LOT 216 SIC-2024-08-19_V1.PDF DOCUMENTS VIEW
Z470 GREAT SAND DUNES- TRUSS REVIEW LETTER - LAYOUT_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
FINAL PLAT RECORDATION (5 MODEL PERMITS)_V1.PDF DOCUMENTS VIEW
PHASE 1 LOT 216_V1.PDF DOCUMENTS VIEW