Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 141462160


Addresses:

7451 S KELLER LN


Inspection Status: Passed

Inspection History: COT - RSEL - Grounding/BondingĀ 

Permit Number - TC-MDP-1023-01704

Inspection Description - COT - RSEL - Grounding/BondingĀ 

Inspection Status - Passed

Date Description Inspector Results Comments
04/03/2024 COT - RSEL - Grounding/BondingĀ  Passed Concrete forms are set, post tension cabling is properly installed per plans, Simpson clips are properly installed and secured to form work per plans, all plumbing pipes are properly wrapped with foam padding, and 20' rebar is placed in footing for Ufer ground. Okay to pour concrete.