Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Complete
Type:
Model Building Permit
Address:
7445 S KELLER LN
Apply Date:
10/24/2023
Applicant:
Joshua Swinney
Description:
SFR 500 Coolidge Model Plan La Escalera

Permit Reviews

Permit Number - TC-MDP-1023-01699
Permit Status: Complete
Permit Description: SFR 500 Coolidge Model Plan La Escalera
Start Date Submittal Complete Date Status  
09/10/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 09/11/2024 REQUIRES RESUBMIT Review Details
11/15/2023 SITE FROM MODEL PERMIT - PRODUCTION v.1 11/21/2023 APPROVED Review Details
09/18/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.2 09/19/2024 APPROVED Review Details

Conditions

Permit Number - TC-MDP-1023-01699
Permit Status: Complete
Permit Description: SFR 500 Coolidge Model Plan La Escalera
Date Description Comments
11/15/2023 Please contact Pima County Addressing to resolve issue. Addressing@pima.gov or 520-724-9512
09/11/2024 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
01/19/2023 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
04/03/2024 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
11/15/2023 Post-Tension Inspection Report is required.
10/25/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
12/12/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
04/03/2024 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.
12/12/2023 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.
09/11/2024 SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED.
01/19/2023 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.
04/03/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-MDP-1023-01699
Permite Description: SFR 500 Coolidge Model Plan La Escalera
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
06/17/2024 COT - BULD - SWG Clearance N/A Not Applicable Not required. No gas to any house in this subdivision.
06/17/2024 COT - RSPL - Gas Pressure Test N/A Not Applicable Not required. No gas to any house in this subdivision.

Completed Inspections

Permit Status: Complete
Permit Number: TC-MDP-1023-01699
Permit Description: SFR 500 Coolidge Model Plan La Escalera
Total Completed Inspections - 19
Date Description Inspector Results Comments
03/28/2024 COT - RSEL - Electrical Underground Passed
04/03/2024 COT - RSPL - Rough Soil Passed
04/11/2024 COT - RSBU - Excavation/Rebar/Zoning Passed
04/11/2024 COT - RSBU - Preslab Passed
04/11/2024 COT - RSEL - Grounding/Bonding Passed
04/29/2024 COT - RSBU - Exterior Clips/Sheathing Passed All masa clips are properly nailed, shear wall clips are properly nailed, plywood sheathing for interior and exterior shear walls are properly nailed, bolts or shot pins are installed in bottom plate on 1st floor and 16P nails are nailed into the bottom plate of the 2nd floor. All straps, H2.5 clips, and stud plates are properly secured. Okay to proceed.
04/29/2024 COT - RSBU - Roof Nailing Passed All trusses and floor joists are properly secured to the top plate with H2.5 clips. All plywood sheathing is secured to the joists and trusses per plan details. Okay to proceed.
06/17/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed Mechanical, electrical, and plumbing rough-in is complete. Okay to proceed with installation of insulation and drywall.
06/17/2024 COT - RSPL - Yard Water Line Passed Main water line is connected to water meter and under street pressure. Okay to proceed.
07/03/2024 COT - RSBU - Interior Shear Bracing Passed 7/3/24: Shear walls are properly screwed per plan requirements. Okay to proceed with tape, texture, and paint.
08/16/2024 BULD - Electrical Clearance Passed Okay to install meter and energize panel. ECO Clearance issued for 7445 E Keller Lane to TEP.
08/22/2024 COT - RSPL - Sewer Passed
09/13/2024 RSBU - Building Progress Passed Contractor has opened up walls in garage at water supply line, plumber has installed 18+ inches of copper pipes from pex line to first solder joint to meet install requirements.
09/26/2024 COT - RSEL - Electrical Final Passed
09/26/2024 COT - RSEL - Outdoor Lighting Passed
09/26/2024 COT - RSME - Mechanical Final Passed
09/26/2024 COT - RSPL - Plumbing Final Passed
09/26/2024 ENGR Engineering Final Passed Cut down clean outs to be as close to flush with final landscaping as possible.
09/26/2024 RSBU - Building Final Passed

Documents

File Name Document Type  
COFO_FINALCOFO_RESIDENTIAL.PDF DOCUMENTS VIEW
ESCALERA- LOT 215 PT REPORT_V1.PDF DOCUMENTS VIEW
LOT 215 SIC-2024-09-16_V2.PDF DOCUMENTS VIEW
SEWER RELEASE DOCUMENT- ESCALERA_V1.PDF DOCUMENTS VIEW
Z500 COOLIDGE- TRUSS REVIEW LETTER - LAYOUT_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
FINAL PLAT RECORDATION (5 MODEL PERMITS)_V1.PDF DOCUMENTS VIEW
PHASE 1 LOT 215_V1.PDF DOCUMENTS VIEW