Permit: TC-MDP-1023-01685
Permit Details
Status:
Inspections Complete
Type:
Model Building Permit
Address:
6168 E CAMPOLINA TR
Address NEW:
6168 E CAMPOLINA TR
Apply Date:
10/23/2023
Applicant:
Helen Ormsby
Description:
Blackhawk H30D Model Plan
Permit Reviews
Permit Number - TC-MDP-1023-01685
Permit Status: Inspections complete
Permit Description: Blackhawk H30D Model Plan
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/21/2026 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 02/12/2026 | APPROVED |
| 08/29/2025 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 08/29/2025 | APPROVED |
| 03/12/2024 | SITE FROM MODEL PERMIT - SUBDIVISION v.2 | 03/22/2024 | APPROVED |
| 10/24/2023 | SITE FROM MODEL PERMIT - SUBDIVISION v.1 | 10/31/2023 | REQUIRES RESUBMIT |
Conditions
Permit Number - TC-MDP-1023-01685
Permit Status: Inspections complete
Permit Description: Blackhawk H30D Model Plan
| Date | Description | Comments |
|---|---|---|
| 10/24/2023 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. | |
| 03/22/2024 | Post-Tension Inspection Report is required. | |
| 10/03/2023 | Post-Tension Inspection Report is required. | |
| 10/18/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
| 03/22/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. | |
| 10/18/2023 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. | |
| 03/22/2024 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. | |
| 09/07/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-1023-01685
Permite Description: Blackhawk H30D Model Plan
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/29/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Partial Pass | 12/29/2025 Partial pass. Need engineer fix/letter submitted to city for foundation at front porch entrance step improperly poured by one foot, wall overhanging and not in contact with concrete. Add H2.5 to interior load-bearing wall at garage, add anchors bolts as marked. |
| 04/07/2026 | ENGR Engineering Final | N/A | Re-inspection required (with fee) | Drainage issue on south side has not been corrected, need to maintain positive drainage throughout, no pooling or crossing of property line is allowed. |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-1023-01685
Permit Description: Blackhawk H30D Model Plan
Total Completed Inspections - 21
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/11/2025 | COT - RSPL - Rough Soil | Passed | 12.11.25 Approved - ok to proceed |
|
| 12/11/2025 | COT - RSPL - Sewer | Passed | 12.11.25 Approved - ok to proceed |
|
| 12/11/2025 | COT - RSPL - Yard Water Line | Passed | 12.11.25 Approved - ok to proceed |
|
| 12/16/2025 | COT - RSBU - Preslab | Passed | 12/16/2025 Approved per plan, added insulation to protect DWV at west wall footing. Okay for concrete placement. |
|
| 12/16/2025 | COT - RSBU - Excavation/Rebar/Zoning | Passed | 12/16/2025 Approved per site plan. |
|
| 12/16/2025 | COT - RSEL - Grounding/Bonding | Passed | 12/16/2025 Bonded to ground rods at MSP. |
|
| 12/16/2025 | BULD - Electrical Clearance | Passed | 12/16/2025 Clearance TEP ECO. |
|
| 12/16/2025 | COT - RSEL - Electrical Underground | Passed | ||
| 12/30/2025 | COT - RSBU - Roof Nailing | Passed | 12/30/2025 Corrections made to prior inspection. |
|
| 01/09/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 01/09/2026 Corrections made to 12/29/25 inspection. |
|
| 01/09/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 01/09/2026 Approved per plan. |
|
| 01/09/2026 | COT - RSPL - Gas Pressure Test | Passed | ||
| 01/16/2026 | COT - RSBU - Interior Shear Bracing | Passed | ||
| 02/11/2026 | COT - BULD - SWG Clearance | Passed | PASSED CLEARANCE SWG 2/11/26 | |
| 02/18/2026 | COT - RSEL - Electrical Final | Passed | 2.18.26 Approved |
|
| 02/18/2026 | COT - RSEL - Outdoor Lighting | Passed | 2.18.26 Approved |
|
| 02/18/2026 | COT - RSME - Mechanical Final | Passed | 2.18.26 Approved |
|
| 02/18/2026 | COT - RSPL - Plumbing Final | Passed | 2.18.26 Approved |
|
| 02/18/2026 | RSBU - Building Final | Passed | 2.18.26 Approved |
|
| 02/18/2026 | RSBU - Building Progress | Passed | 2.18.26 Approved |
|
| 04/27/2026 | ENGR Engineering Final | Passed | Site is complete in accordance with approved plans. |