Permit: TC-MDP-1023-01683
Permit Details
Status:
Inspections Complete
Type:
Model Building Permit
Address:
6203 E CAMPOLINA TR
Address NEW:
6203 E CAMPOLINA TR
Apply Date:
10/19/2023
Applicant:
Helen Ormsby
Description:
Blackhawk H30M Model Plan
Permit Reviews
Permit Number - TC-MDP-1023-01683
Permit Status: Inspections complete
Permit Description: Blackhawk H30M Model Plan
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 10/29/2025 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 10/30/2025 | APPROVED |
| 08/28/2025 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 08/29/2025 | APPROVED |
| 02/27/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 03/04/2024 | APPROVED |
| 10/23/2023 | SITE FROM MODEL PERMIT - SUBDIVISION v.1 | 10/27/2023 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-1023-01683
Permit Status: Inspections complete
Permit Description: Blackhawk H30M Model Plan
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 09/07/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Conditions
Permit Number - TC-MDP-1023-01683
Permit Status: Inspections complete
Permit Description: Blackhawk H30M Model Plan
| Date | Description | Comments |
|---|---|---|
| 10/23/2023 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. | |
| 10/27/2023 | Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact. | |
| 10/23/2023 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. | |
| 08/29/2025 | Post-Tension Inspection Report is required. | |
| 10/03/2023 | Post-Tension Inspection Report is required. | |
| 10/04/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
| 10/04/2023 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. | |
| 08/29/2025 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-1023-01683
Permite Description: Blackhawk H30M Model Plan
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/02/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Re-inspection required | 10/2/25: Staples at shear walls must not over penetrate sheathing and shall be no closer than 3/8" from edge. Staples must be spaced 3" o.c at all thermo-ply shearwalls. Anchor bolt spacing at shear walls must be 22" o.c, 16dx2 1/2" nails must be used at HTT4. stud at first floor garage wall must be properly secured at shearwall |
Completed Inspections
Permit Status: Inspections Complete
Permit Number: TC-MDP-1023-01683
Permit Description: Blackhawk H30M Model Plan
Total Completed Inspections - 21
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/10/2025 | COT - RSPL - Rough Soil | Passed | 9.10.25 Approved |
|
| 09/10/2025 | COT - RSPL - Sewer | Passed | 9.10.25 Approved |
|
| 09/10/2025 | COT - RSPL - Yard Water Line | Passed | 9.10.25 Approved |
|
| 09/17/2025 | COT - RSEL - Grounding/Bonding | Passed | ||
| 09/17/2025 | COT - RSEL - Electrical Underground | Passed | ||
| 09/17/2025 | COT - RSBU - Excavation/Rebar/Zoning | Passed | 9.17.2025 Verified setbacks per plan. |
|
| 09/17/2025 | COT - RSBU - Preslab | Passed | 9.17.2025 Verified per plan, okay for concrete placement. |
|
| 09/30/2025 | COT - RSBU - Roof Nailing | Passed | ||
| 10/03/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 10.3.25 Corrections made APPROVED |
|
| 10/08/2025 | BULD - Electrical Clearance | Passed | 10/8/25: ECO | |
| 10/13/2025 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | ||
| 10/13/2025 | COT - RSPL - Gas Pressure Test | Passed | ||
| 10/21/2025 | COT - RSBU - Interior Shear Bracing | Passed | 10/21/25 corrections made | |
| 11/18/2025 | COT - BULD - SWG Clearance | Passed | 11.18.2025 Clearance SWG. |
|
| 11/25/2025 | ENGR Engineering Final | Passed | ||
| 12/02/2025 | COT - RSEL - Electrical Final | Passed | 12-2-25: mechanical, plumbing, electrical, outdoor lighting, & building final approved. | |
| 12/02/2025 | COT - RSEL - Outdoor Lighting | Passed | 12-2-25: mechanical, plumbing, electrical, outdoor lighting, & building final approved. | |
| 12/02/2025 | COT - RSME - Mechanical Final | Passed | 12-2-25: mechanical, plumbing, electrical, outdoor lighting, & building final approved. | |
| 12/02/2025 | COT - RSPL - Plumbing Final | Passed | 12-2-25: mechanical, plumbing, electrical, outdoor lighting, & building final approved. | |
| 12/02/2025 | RSBU - Building Final | Passed | 12-2-25: mechanical, plumbing, electrical, outdoor lighting, & building final approved. | |
| 12/02/2025 | RSBU - Building Progress | Passed | 12-2-25: mechanical, plumbing, electrical, outdoor lighting, & building final approved. |