Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Details

Status:
Inspections Complete
Type:
Model Building Permit
Address NEW:
6422 S AMBARELLA DR
Apply Date:
10/17/2023
Applicant:
Celina Rodriguez
Description:
VC 1465-130

Permit Reviews

Permit Number - TC-MDP-1023-01620
Permit Status: Inspections complete
Permit Description: VC 1465-130
Start Date Submittal Complete Date Status  
10/17/2023 SITE FROM MODEL PERMIT - SUBDIVISION v.1 10/23/2023 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-MDP-1023-01620
Permit Status: Inspections complete
Permit Description: VC 1465-130
Total Outstanding Activity Conditions - 5
Date Name
04/03/2023 Post-Tension Inspection Report is required.
04/03/2023 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.
08/11/2023 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.
10/17/2023 Post-Installed Anchor Inspection Report is required.
10/17/2023 SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED.

Conditions

Permit Number - TC-MDP-1023-01620
Permit Status: Inspections complete
Permit Description: VC 1465-130
Date Description Comments
10/23/2023 Contractor with active Arizona Contractor's License for specified scope of work required prior to issuance of permit. Contractor must have a TDC Online account and be added to the permit as a contact.
08/11/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
10/13/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.

Outstanding Inspections

Permit Status: Inspections Complete
Permit Number: TC-MDP-1023-01620
Permite Description: VC 1465-130
Total Outstanding Inspections - 5
Last Inspection Date Description Inspector Results Comments
12/22/2023 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Re-inspection required Attic access requirements not met, missing 1.5" VTR for kitchen sink per plans. Insulation has been installed before passing intermediate. Remove ALL insulation from house.
01/02/2024 COT - RSBU - Interior Shear Bracing N/A Re-inspection required Cancelled per Karl.
1/2/24: no plans on site.
01/02/2024 BULD - Electrical Clearance N/A Not Ready 1/2/24: Not ready
03/06/2024 COT - RSME - Mechanical Final N/A Not Ready Mechanical vent in master not installed, landscaping grade
3/6/24: Not ready
03/06/2024 RSBU - Building Final N/A Not Ready Mechanical vent in master not installed, landscaping grade
3/6/24: Not ready

Completed Inspections

Permit Status: Inspections Complete
Permit Number: TC-MDP-1023-01620
Permit Description: VC 1465-130
Total Completed Inspections - 20
Date Description Inspector Results Comments
11/07/2023 COT - RSPL - Rough Soil Passed
11/07/2023 COT - RSPL - Sewer Passed
11/07/2023 COT - RSPL - Yard Water Line Passed
11/09/2023 COT - RSEL - Electrical Underground Passed
11/09/2023 COT - RSEL - Grounding/Bonding Passed
11/13/2023 COT - RSBU - Preslab Passed
11/14/2023 COT - RSBU - Excavation/Rebar/Zoning Passed
11/29/2023 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 11/29/23: All items from the 11/24/23 have been corrected. Okay to proceed with exterior dry-in of walls and roof.
11/29/2023 COT - RSBU - Roof Nailing Passed 11/29/23: All items from the 11/24/23 have been corrected. Okay to proceed with exterior dry-in of walls and roof.
12/20/2023 COT - RSPL - Gas Pressure Test Passed
01/03/2024 COT - RSBU - Interior Shear Bracing Passed 1/3/2024. Approved.
01/08/2024 BULD - Electrical Clearance Passed
02/07/2024 COT - BULD - SWG Clearance Passed
03/01/2024 COT - RSEL - Electrical Final Passed
03/01/2024 COT - RSEL - Outdoor Lighting Passed
03/01/2024 COT - RSPL - Plumbing Final Passed
03/01/2024 RSBU - Building Progress Passed
03/08/2024 COT - RSME - Mechanical Final Passed
03/08/2024 RSBU - Building Final Passed
03/08/2024 ENGR Engineering Final Passed