Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections
Type:
Model Building Permit
Address NEW:
9503 E FRIEDEL DR
Apply Date:
10/17/2025
Applicant:
Angelic Wajszcuk
Description:
Indiana Dunes Model Plan La Escalera (Model master plan TC-MDP-1222-00130) Rev 3

Permit Reviews

Permit Number - TC-MDP-0925-00599
Permit Status: Inspections
Permit Description: Indiana Dunes Model Plan La Escalera (Model master plan TC-MDP-1222-00130) Rev 3
Start Date Submittal Complete Date Status  
10/17/2025 SITE FROM MODEL PERMIT - SUBDIVISION v.1 10/22/2025 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-MDP-0925-00599
Permit Status: Inspections
Permit Description: Indiana Dunes Model Plan La Escalera (Model master plan TC-MDP-1222-00130) Rev 3
Total Outstanding Activity Conditions - 3
Date Name
09/23/2025 Post-Tension Inspection Report is required.
09/23/2025 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/
10/17/2025 SPECIAL INSPECTION FOR SITE PREPARATION IS REQUIRED.

Conditions

Permit Number - TC-MDP-0925-00599
Permit Status: Inspections
Permit Description: Indiana Dunes Model Plan La Escalera (Model master plan TC-MDP-1222-00130) Rev 3
Date Description Comments
09/23/2025 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.
09/23/2025 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-MDP-0925-00599
Permite Description: Indiana Dunes Model Plan La Escalera (Model master plan TC-MDP-1222-00130) Rev 3
Total Outstanding Inspections - 4
Last Inspection Date Description Inspector Results Comments
08/27/2026 COT - BULD - SWG Clearance N/A Not Applicable
08/27/2026 COT - RSPL - Gas Pressure Test N/A Not Applicable
10/02/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Not Ready 10/2/2026 nailing cannot penetrate more than an 1/8" throughout all shear walls. Add nails to loose shear marked areas. Add draft stopping at all empty cavities. Add 2x studs between floor trusses to provide the continuous loads from the second floor. Missing exterior shear at east end behind garage shear. Ensure shear continues through belly band per detail 2/SD2. Add shear above at belly band section east end above 10' shear wall. Per detail SD2/12 ledger is not the correct size or nailing to each stud. Add 2x's at marked areas underneath floor trusses. Add hanger to flor truss near stair. Add 2x's at both ends for front end of house girder trusses. Ensure they are all continuous. Stopped inspection other items may apply. Note: second floor was not walked.
10/02/2026 COT - RSBU - Roof Nailing N/A Not Ready 10/2/2026 nailing cannot penetrate more than an 1/8" throughout all shear walls. Add nails to loose shear marked areas. Add draft stopping at all empty cavities. Add 2x studs between floor trusses to provide the continuous loads from the second floor. Missing exterior shear at east end behind garage shear. Ensure shear continues through belly band per detail 2/SD2. Add shear above at belly band section east end above 10' shear wall. Per detail SD2/12 ledger is not the correct size or nailing to each stud. Add 2x's at marked areas underneath floor trusses. Add hanger to flor truss near stair. Add 2x's at both ends for front end of house girder trusses. Ensure they are all continuous. Stopped inspection other items may apply. Note: second floor was not walked.

Completed Inspections

Permit Status: Inspections
Permit Number: TC-MDP-0925-00599
Permit Description: Indiana Dunes Model Plan La Escalera (Model master plan TC-MDP-1222-00130) Rev 3
Total Completed Inspections - 6
Date Description Inspector Results Comments
08/27/2026 COT - RSPL - Sewer Passed 8-27-26 OK to cover shading is required
08/27/2026 COT - RSPL - Rough Soil Passed 8-27-26 OK to cover shading is required
08/27/2026 COT - RSPL - Yard Water Line Passed 8-27-26 OK to cover shading is required
09/08/2026 COT - RSBU - Excavation/Rebar/Zoning Passed 9-8-26 All corrections were made during the time of the inspection OK to proceed
09/08/2026 COT - RSBU - Preslab Passed 9-8-26 All corrections were made during the time of the inspection OK to proceed
09/08/2026 COT - RSEL - Electrical Underground Passed

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
LA ESCALERA (MIRADOR) LOT 123_V1.PDF DOCUMENTS VIEW
PHASE 1A LOT 123 SIC-2025-10-17_V1.PDF DOCUMENTS VIEW