Permit: TC-MDP-0925-00599
Permit Details
Status:
Inspections
Type:
Model Building Permit
Address:
9503 E FRIEDEL DR
Address NEW:
9503 E FRIEDEL DR
Apply Date:
10/17/2025
Applicant:
Angelic Wajszcuk
Description:
Indiana Dunes Model Plan La Escalera (Model master plan TC-MDP-1222-00130) Rev 3
Permit Reviews
Permit Number - TC-MDP-0925-00599
Permit Status: Inspections
Permit Description: Indiana Dunes Model Plan La Escalera (Model master plan TC-MDP-1222-00130) Rev 3
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 10/17/2025 | SITE FROM MODEL PERMIT - SUBDIVISION v.1 | 10/22/2025 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0925-00599
Permit Status: Inspections
Permit Description: Indiana Dunes Model Plan La Escalera (Model master plan TC-MDP-1222-00130) Rev 3
Total Outstanding Activity Conditions - 3
| Date | Name |
|---|---|
| 09/23/2025 | Post-Tension Inspection Report is required. |
| 09/23/2025 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/ |
| 10/17/2025 | SPECIAL INSPECTION FOR SITE PREPARATION IS REQUIRED. |
Conditions
Permit Number - TC-MDP-0925-00599
Permit Status: Inspections
Permit Description: Indiana Dunes Model Plan La Escalera (Model master plan TC-MDP-1222-00130) Rev 3
| Date | Description | Comments |
|---|---|---|
| 09/23/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. | |
| 09/23/2025 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0925-00599
Permite Description: Indiana Dunes Model Plan La Escalera (Model master plan TC-MDP-1222-00130) Rev 3
Total Outstanding Inspections - 4
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/27/2026 | COT - BULD - SWG Clearance | N/A | Not Applicable | |
| 08/27/2026 | COT - RSPL - Gas Pressure Test | N/A | Not Applicable | |
| 10/02/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Not Ready | 10/2/2026 nailing cannot penetrate more than an 1/8" throughout all shear walls. Add nails to loose shear marked areas. Add draft stopping at all empty cavities. Add 2x studs between floor trusses to provide the continuous loads from the second floor. Missing exterior shear at east end behind garage shear. Ensure shear continues through belly band per detail 2/SD2. Add shear above at belly band section east end above 10' shear wall. Per detail SD2/12 ledger is not the correct size or nailing to each stud. Add 2x's at marked areas underneath floor trusses. Add hanger to flor truss near stair. Add 2x's at both ends for front end of house girder trusses. Ensure they are all continuous. Stopped inspection other items may apply. Note: second floor was not walked. |
| 10/02/2026 | COT - RSBU - Roof Nailing | N/A | Not Ready | 10/2/2026 nailing cannot penetrate more than an 1/8" throughout all shear walls. Add nails to loose shear marked areas. Add draft stopping at all empty cavities. Add 2x studs between floor trusses to provide the continuous loads from the second floor. Missing exterior shear at east end behind garage shear. Ensure shear continues through belly band per detail 2/SD2. Add shear above at belly band section east end above 10' shear wall. Per detail SD2/12 ledger is not the correct size or nailing to each stud. Add 2x's at marked areas underneath floor trusses. Add hanger to flor truss near stair. Add 2x's at both ends for front end of house girder trusses. Ensure they are all continuous. Stopped inspection other items may apply. Note: second floor was not walked. |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0925-00599
Permit Description: Indiana Dunes Model Plan La Escalera (Model master plan TC-MDP-1222-00130) Rev 3
Total Completed Inspections - 6
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/27/2026 | COT - RSPL - Sewer | Passed | 8-27-26 OK to cover shading is required | |
| 08/27/2026 | COT - RSPL - Rough Soil | Passed | 8-27-26 OK to cover shading is required | |
| 08/27/2026 | COT - RSPL - Yard Water Line | Passed | 8-27-26 OK to cover shading is required | |
| 09/08/2026 | COT - RSBU - Excavation/Rebar/Zoning | Passed | 9-8-26 All corrections were made during the time of the inspection OK to proceed | |
| 09/08/2026 | COT - RSBU - Preslab | Passed | 9-8-26 All corrections were made during the time of the inspection OK to proceed | |
| 09/08/2026 | COT - RSEL - Electrical Underground | Passed |