Permit: TC-MDP-0925-00594
Permit Details
Status:
Inspections
Type:
Model Building Permit
Address:
9532 E FRIEDEL DR
Address NEW:
9532 E FRIEDEL DR
Apply Date:
09/26/2025
Applicant:
Angelic Wajszcuk
Description:
Arches Model Plan (Model master plan TC-MDP-1222-00129) Rev3
Permit Reviews
Permit Number - TC-MDP-0925-00594
Permit Status: Inspections
Permit Description: Arches Model Plan (Model master plan TC-MDP-1222-00129) Rev3
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/26/2025 | SITE FROM MODEL PERMIT - SUBDIVISION v.1 | 10/13/2025 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0925-00594
Permit Status: Inspections
Permit Description: Arches Model Plan (Model master plan TC-MDP-1222-00129) Rev3
Total Outstanding Activity Conditions - 2
| Date | Name |
|---|---|
| 09/23/2025 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/ |
| 09/26/2025 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
Conditions
Permit Number - TC-MDP-0925-00594
Permit Status: Inspections
Permit Description: Arches Model Plan (Model master plan TC-MDP-1222-00129) Rev3
| Date | Description | Comments |
|---|---|---|
| 09/26/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. | |
| 09/26/2025 | Post-Installed Anchor Inspection Report is required. | |
| 09/23/2025 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. | |
| 09/26/2025 | SPECIAL INSPECTION FOR SITE PREPARATION IS REQUIRED. | |
| 10/15/2025 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0925-00594
Permite Description: Arches Model Plan (Model master plan TC-MDP-1222-00129) Rev3
Total Outstanding Inspections - 4
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/06/2026 | COT - BULD - SWG Clearance | N/A | Not Applicable | |
| 07/06/2026 | COT - RSPL - Gas Pressure Test | N/A | Not Applicable | N/A |
| 08/11/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Re-inspection required | 08/11/2026 Add anchor bolts at marked locations, loose anchor bolts throughput, add missing 6" screw to roof truss on west wall. |
| 09/23/2026 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | 9/23/26: loose anchor bolts throughout 1st floor exterior walls, lower thermostat height to 48" o.c., provide laundry exhaust support at 4' intervals, tape flex tear at kitchen, provide support at marked location, fire foam top plate penetration at stair-see marked location, fire foam all around upstairs chutes, upstairs shower not under test, provide approved set of plans. Stopped inspection-additional items may be noted. |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0925-00594
Permit Description: Arches Model Plan (Model master plan TC-MDP-1222-00129) Rev3
Total Completed Inspections - 8
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/06/2026 | COT - RSPL - Rough Soil | Passed | ||
| 07/06/2026 | COT - RSPL - Sewer | Passed | ||
| 07/06/2026 | COT - RSPL - Yard Water Line | Passed | ||
| 07/09/2026 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
| 07/09/2026 | COT - RSBU - Preslab | Passed | 07/09/2026 Approved per site plan and reinforcement. Okay for concrete placement. |
|
| 07/09/2026 | COT - RSEL - Electrical Underground | Passed | ||
| 08/11/2026 | COT - RSBU - Roof Nailing | Passed | ||
| 09/23/2026 | BULD - Electrical Clearance | Passed | 9/23/26: okay to energize-ECO clearance issued to TEP. |