Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Inspections
Type:
Model Building Permit
Address NEW:
9502 E FRIEDEL DR
Apply Date:
10/17/2025
Applicant:
Angelic Wajszcuk
Description:
Black Mountain model SFR Escalara (Model master plan TC-MDP-1222-00136) Rev 3

Permit Reviews

Permit Number - TC-MDP-0925-00592
Permit Status: Inspections
Permit Description: Black Mountain model SFR Escalara (Model master plan TC-MDP-1222-00136) Rev 3
Start Date Submittal Complete Date Status  
10/17/2025 SITE FROM MODEL PERMIT - SUBDIVISION v.1 10/24/2025 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-MDP-0925-00592
Permit Status: Inspections
Permit Description: Black Mountain model SFR Escalara (Model master plan TC-MDP-1222-00136) Rev 3
Total Outstanding Activity Conditions - 4
Date Name
09/23/2025 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/
10/17/2025 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
10/17/2025 Post-Installed Anchor Inspection Report is required.
10/17/2025 SPECIAL INSPECTION FOR SITE PREPARATION IS REQUIRED.

Conditions

Permit Number - TC-MDP-0925-00592
Permit Status: Inspections
Permit Description: Black Mountain model SFR Escalara (Model master plan TC-MDP-1222-00136) Rev 3
Date Description Comments
10/17/2025 Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit.
09/23/2025 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-MDP-0925-00592
Permite Description: Black Mountain model SFR Escalara (Model master plan TC-MDP-1222-00136) Rev 3
Total Outstanding Inspections - 3
Last Inspection Date Description Inspector Results Comments
08/27/2026 COT - BULD - SWG Clearance N/A Not Applicable 8-27-26 OK to cover shading is required
08/27/2026 COT - RSPL - Gas Pressure Test N/A Not Applicable
09/21/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Re-inspection required 9-21-26 shop pins are required at marked locations* coil strap missing per detail SD-2.52 at back window * missing nails at sheer wall upstairs south east corner* missing nails at Jo2 south east corner *missing hanger in primary bedroom at J01* missing nails at shear wall located west wall. Truss calcs and roof nailing walked OK and passed. Reinspection required

Completed Inspections

Permit Status: Inspections
Permit Number: TC-MDP-0925-00592
Permit Description: Black Mountain model SFR Escalara (Model master plan TC-MDP-1222-00136) Rev 3
Total Completed Inspections - 7
Date Description Inspector Results Comments
08/27/2026 COT - RSPL - Rough Soil Passed 8-27-26 OK to cover shading is required
08/27/2026 COT - RSPL - Sewer Passed 8-27-26 OK to cover shading is required
08/27/2026 COT - RSPL - Yard Water Line Passed 8-27-26 OK to cover shading is required
09/04/2026 COT - RSBU - Excavation/Rebar/Zoning Passed 9-4-26 All corrections were made during inspection. OK to pour
09/04/2026 COT - RSBU - Preslab Passed 9-4-26 All corrections were made during inspection. OK to pour
09/04/2026 COT - RSEL - Electrical Underground Passed
09/21/2026 COT - RSBU - Roof Nailing Passed 9-21-26 roof inspection pass OK to proceed

Documents

File Name Document Type  
LA ESCALERA (MIRADOR) LOT 83-(BLACK MTN_REPLACED BIG BEND)_V1.PDF DOCUMENTS VIEW
PHASE 1A LOT 83 SIC-2025-10-17_V1.PDF DOCUMENTS VIEW