Permit: TC-MDP-0925-00591
Permit Details
Status:
Inspections
Type:
Model Building Permit
Address:
9550 E FRIEDEL DR
Address NEW:
9550 E FRIEDEL DR
Apply Date:
09/26/2025
Applicant:
Angelic Wajszcuk
Description:
Black Mountain model SFR Escalara (Model master plan TC-MDP-1222-00136) Rev 3
Permit Reviews
Permit Number - TC-MDP-0925-00591
Permit Status: Inspections
Permit Description: Black Mountain model SFR Escalara (Model master plan TC-MDP-1222-00136) Rev 3
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/26/2025 | SITE FROM MODEL PERMIT - SUBDIVISION v.1 | 10/13/2025 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0925-00591
Permit Status: Inspections
Permit Description: Black Mountain model SFR Escalara (Model master plan TC-MDP-1222-00136) Rev 3
Total Outstanding Activity Conditions - 4
| Date | Name |
|---|---|
| 09/23/2025 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/ |
| 09/26/2025 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
| 09/26/2025 | Post-Installed Anchor Inspection Report is required. |
| 09/26/2025 | SPECIAL INSPECTION FOR SITE PREPARATION IS REQUIRED. |
Conditions
Permit Number - TC-MDP-0925-00591
Permit Status: Inspections
Permit Description: Black Mountain model SFR Escalara (Model master plan TC-MDP-1222-00136) Rev 3
| Date | Description | Comments |
|---|---|---|
| 09/26/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. | |
| 09/23/2025 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. | |
| 10/15/2025 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0925-00591
Permite Description: Black Mountain model SFR Escalara (Model master plan TC-MDP-1222-00136) Rev 3
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/06/2026 | COT - BULD - SWG Clearance | N/A | Not Applicable | |
| 07/06/2026 | COT - RSPL - Gas Pressure Test | N/A | Not Applicable | |
| 07/30/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Not Ready | Holdowns at garage have more than an 1” blowout. Engineer fix is required. Belly band requires nails at every 3”. Provide anchor bolts at marked locations due to compromised masa clips. Second floor t ply provide 3” o.c staples. Loose shear at primary room. Provide missing screws to trusses marked areas. Provide nails at bottom plate shear wall second floor per schedule. Add nails from trimmer to king studs per schedule. Add coil strap west wall perimeter to shear wall. Provide nails at exterior walls per schedule. Properly install deflector screws. 7/30/2026 |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0925-00591
Permit Description: Black Mountain model SFR Escalara (Model master plan TC-MDP-1222-00136) Rev 3
Total Completed Inspections - 7
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/06/2026 | COT - RSPL - Rough Soil | Passed | ||
| 07/06/2026 | COT - RSPL - Sewer | Passed | ||
| 07/06/2026 | COT - RSPL - Yard Water Line | Passed | ||
| 07/10/2026 | COT - RSBU - Excavation/Rebar/Zoning | Passed | ||
| 07/10/2026 | COT - RSBU - Preslab | Passed | 07/10/2026 Approved per plan and reinforcement. Ok for concrete placement. |
|
| 07/10/2026 | COT - RSEL - Electrical Underground | Passed | ||
| 07/30/2026 | COT - RSBU - Roof Nailing | Passed |