Permit: TC-MDP-0925-00559
Permit Details
Status:
Inspections
Type:
Model Building Permit
Address:
1168 E LIGGINS ST
Address NEW:
1168 E LIGGINS ST
Apply Date:
10/07/2025
Applicant:
Mark Alteri
Description:
PV 1882 SFR (Model master plan TC-MDP-0124-00059)
Permit Reviews
Permit Number - TC-MDP-0925-00559
Permit Status: Inspections
Permit Description: PV 1882 SFR (Model master plan TC-MDP-0124-00059)
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/13/2025 | ADMINISTRATIVE v.3 | 11/13/2025 | APPROVED |
| 11/04/2025 | ADMINISTRATIVE v.2 | 11/04/2025 | REQUIRES RESUBMIT |
| 10/27/2025 | SITE FROM MODEL PERMIT - PRODUCTION v.4 | 10/29/2025 | APPROVED |
| 10/16/2025 | SITE FROM MODEL PERMIT - PRODUCTION v.2 | 10/17/2025 | REQUIRES RESUBMIT |
| 10/07/2025 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 10/16/2025 | REQUIRES RESUBMIT |
| 10/30/2025 | ADMINISTRATIVE v.1 | 10/30/2025 | REQUIRES RESUBMIT |
| 10/29/2025 | RESTAMP - RESIDENTIAL v.1 | 10/30/2025 | APPROVED |
| 10/20/2025 | SITE FROM MODEL PERMIT - PRODUCTION v.3 | 10/23/2025 | REQUIRES RESUBMIT |
Outstanding Activity Conditions
Permit Number - TC-MDP-0925-00559
Permit Status: Inspections
Permit Description: PV 1882 SFR (Model master plan TC-MDP-0124-00059)
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 09/18/2025 | Post-Tension Inspection Report is required. |
Conditions
Permit Number - TC-MDP-0925-00559
Permit Status: Inspections
Permit Description: PV 1882 SFR (Model master plan TC-MDP-0124-00059)
| Date | Description | Comments |
|---|---|---|
| 10/17/2025 | The Contractor you have added to your permit cannot be verified. Please contact staff to have the ROC number added to the account. | |
| 09/18/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. | |
| 09/18/2025 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. | |
| 09/18/2025 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/ | |
| 09/18/2025 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0925-00559
Permite Description: PV 1882 SFR (Model master plan TC-MDP-0124-00059)
Total Outstanding Inspections - 3
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/24/2025 | COT - RSPL - Yard Water Line | N/A | Re-inspection required | 11.24.25 Muddy soil conditions - cannot verify leaks Leak at main water line present Stack not full No plans on site |
| 01/27/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Re-inspection required | 1/27/26: Anchor bolts must be spaced at 24"O.C at shear wall 5 at first floor throughout, Anchor bolts required 12" from edge of sill plate, anchor bolts required to be spaced no more then 48" o.c at non-shear walls, anchor bolts at shear wall in garage must be exposed to verify spacing, per detail SD3/3 H2.5 required at floor truss by pwd room 1st floor, per SD3/1 CS16 strap required at 48" o.c at exterior rim blocking, cs16 at garage opening must be 54", shear wall fasteners shall be 3/8" from edge and shall not penetrate more than 1/8", shear wall fasteners must be installed per schedule, anchor bolts required 12" from hold down, 2nd floor holdowns missing throughout and shall be appropriate length with correct number of fasteners, STOPPED INSPECTION MORE ITEMS MAY BE ADDED. |
| 01/27/2026 | COT - RSBU - Roof Nailing | N/A | Re-inspection required | 1/27/26: Anchor bolts must be spaced at 24"O.C at shear wall 5 at first floor throughout, Anchor bolts required 12" from edge of sill plate, anchor bolts required to be spaced no more then 48" o.c at non-shear walls, anchor bolts at shear wall in garage must be exposed to verify spacing, per detail SD3/3 H2.5 required at floor truss by pwd room 1st floor, per SD3/1 CS16 strap required at 48" o.c at exterior rim blocking, cs16 at garage opening must be 54", shear wall fasteners shall be 3/8" from edge and shall not penetrate more than 1/8", shear wall fasteners must be installed per schedule, anchor bolts required 12" from hold down, 2nd floor holdowns missing throughout and shall be appropriate length with correct number of fasteners, STOPPED INSPECTION MORE ITEMS MAY BE ADDED. |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0925-00559
Permit Description: PV 1882 SFR (Model master plan TC-MDP-0124-00059)
Total Completed Inspections - 6
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/25/2025 | COT - RSPL - Backwater Valve | Passed | 11.25.25 Approved |
|
| 11/25/2025 | COT - RSPL - Rough Soil | Passed | 11.25.25 Approved |
|
| 11/25/2025 | COT - RSPL - Sewer | Passed | 11.25.25 Approved |
|
| 12/02/2025 | COT - RSEL - Electrical Underground | Passed | ||
| 12/02/2025 | COT - RSBU - Preslab | Passed | Ensure slab area is termite. | |
| 12/02/2025 | COT - RSBU - Excavation/Rebar/Zoning | Passed |