Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Inspections
Type:
Model Building Permit
Address:
2739 S AYALA ST
Address NEW:
2739 S AYALA ST
Apply Date:
01/20/2026
Applicant:
Mark Alteri
Description:
PV 1074 SFR (Model master plan TC-MDP-0124-00022)

Permit Reviews

Permit Number - TC-MDP-0925-00554
Permit Status: Inspections
Permit Description: PV 1074 SFR (Model master plan TC-MDP-0124-00022)
Start Date Submittal Complete Date Status  
01/23/2026 SITE FROM MODEL PERMIT - PRODUCTION v.1 01/30/2026 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-MDP-0925-00554
Permit Status: Inspections
Permit Description: PV 1074 SFR (Model master plan TC-MDP-0124-00022)
Total Outstanding Activity Conditions - 1
Date Name
09/18/2025 Post-Tension Inspection Report is required.

Conditions

Permit Number - TC-MDP-0925-00554
Permit Status: Inspections
Permit Description: PV 1074 SFR (Model master plan TC-MDP-0124-00022)
Date Description Comments
09/18/2025 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.
09/18/2025 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/
09/18/2025 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-MDP-0925-00554
Permite Description: PV 1074 SFR (Model master plan TC-MDP-0124-00022)
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
03/12/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing N/A Re-inspection required 3-12-26: add shots pins at marked locations, add nailing to exterior sheathing above garage, missing 3-3/8"x5" lad screws at back patio-see SD3.1 Detail 16. Plans call for a 2x8 continuous rim on east exterior wall of kitchen door -a 2x6 was used with a 2" trim. Stopped inspection -additional items may be added. Also, provide a ladder to inspect roof, cs 16 straps missing at inside of back patio doors-see sd3.1& sd2/detail 1.

Completed Inspections

Permit Status: Inspections
Permit Number: TC-MDP-0925-00554
Permit Description: PV 1074 SFR (Model master plan TC-MDP-0124-00022)
Total Completed Inspections - 8
Date Description Inspector Results Comments
02/13/2026 COT - RSPL - Rough Soil Passed Passed 2/12/26
02/13/2026 COT - RSPL - Sewer Passed Passed 2/12/26
02/13/2026 COT - RSPL - Yard Water Line Passed Passed 2/12/26
02/25/2026 COT - RSBU - Excavation/Rebar/Zoning Passed
02/25/2026 COT - RSBU - Preslab Passed Ensure slab area is termite treated.
02/25/2026 COT - RSEL - Electrical Underground Passed
03/17/2026 COT - RSBU - Roof Nailing Passed 3/17/2026
Corrections made to prior inspection. Walked rest of house, verified roof nailing and truss calcs.
03/17/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 3/17/2026
Corrections made to prior inspection. Walked rest of house, verified roof nailing and truss calcs.

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
PRL 28 PT CERT-2026-01-20_V1.PDF DOCUMENTS VIEW
PRL PP FOR SUBMITTAL_V1.PDF DOCUMENTS VIEW