03/12/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 3-12-26: add shots pins at marked locations, add nailing to exterior sheathing above garage, missing 3-3/8"x5" lad screws at back patio-see SD3.1 Detail 16. Plans call for a 2x8 continuous rim on east exterior wall of kitchen door -a 2x6 was used with a 2" trim. Stopped inspection -additional items may be added. Also, provide a ladder to inspect roof, cs 16 straps missing at inside of back patio doors-see sd3.1& sd2/detail 1.
03/17/2026 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 3/17/2026
Corrections made to prior inspection. Walked rest of house, verified roof nailing and truss calcs.