Permit: TC-MDP-0925-00506
Permit Details
Status:
Inspections
Type:
Model Building Permit
Address:
9961 E LEBARON DR
Address NEW:
9961 E LEBARON DR
Apply Date:
06/05/2026
Applicant:
Celina Rodriguez
Description:
Mirador Ridge Skies 1708 Plan (TC-MDP-0825-00416)
Permit Reviews
Permit Number - TC-MDP-0925-00506
Permit Status: Inspections
Permit Description: Mirador Ridge Skies 1708 Plan (TC-MDP-0825-00416)
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/10/2026 | SITE FROM MODEL PERMIT - SUBDIVISION v.1 | 06/16/2026 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0925-00506
Permit Status: Inspections
Permit Description: Mirador Ridge Skies 1708 Plan (TC-MDP-0825-00416)
Total Outstanding Activity Conditions - 4
| Date | Name |
|---|---|
| 06/16/2026 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. |
| 06/16/2026 | Post-Installed Anchor Inspection Report is required. |
| 09/02/2025 | Submit the Air Leakage & Duct Tightness Test Report completed by an Approved Special Inspector prior to Final Inspections. |
| 09/02/2025 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
Conditions
Permit Number - TC-MDP-0925-00506
Permit Status: Inspections
Permit Description: Mirador Ridge Skies 1708 Plan (TC-MDP-0825-00416)
| Date | Description | Comments |
|---|---|---|
| 09/02/2025 | Contractor with active Arizona Contractor's License for specified scope of work, or a signed Owner Builder Affidavit is required prior to issuance of permit. The Affidavit form is available at https://www.tucsonaz.gov/Departments/Planning-Development-Services/Permits/Residential-Permits. Contractor or Owner must have a TDC Online account and be added to the permit as the correct contact type https://www.tucsonaz.gov/files/sharedassets/public/v/2/pdsd/documents/tdc-faq/new-pdfs/adding-additional-contacts.pdf. If you are providing an Owner Builder Affidavit, the owner MUST be attached as a contact on the permit. | |
| 09/02/2025 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. | |
| 09/02/2025 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/ |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0925-00506
Permite Description: Mirador Ridge Skies 1708 Plan (TC-MDP-0825-00416)
Total Outstanding Inspections - 5
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/09/2026 | COT - RSEL - Grounding/Bonding | N/A | Partial Pass | 7/9/26: PARTIAL FOR UFER ONLY |
| 07/08/2026 | COT - RSBU - Excavation/Rebar/Zoning | N/A | Re-inspection required | 7-8-2026 Reinforcement shall extend 2’ on each side of hold down. Pad must be properly compacted. PT cable shall not be exposed no more than 12” on stationary end & no more than 1” on pull end. End caps missing at stationary end. Footing shall be 12” in width as well as12” in height. All plumbing shall be wrapped at slab. Damaged sheathing at PT cable must be protected. Re-inspection is required. |
| 07/08/2026 | COT - RSBU - Preslab | N/A | Re-inspection required | 7-8-2026 Reinforcement shall extend 2’ on each side of hold down. Pad must be properly compacted. PT cable shall not be exposed no more than 12” on stationary end & no more than 1” on pull end. End caps missing at stationary end. Footing shall be 12” in width as well as12” in height. All plumbing shall be wrapped at slab. Damaged sheathing at PT cable must be protected. Re-inspection is required. |
| 07/08/2026 | COT - RSEL - Electrical Underground | N/A | Not Applicable | |
| 07/21/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | N/A | Re-inspection required | Provide additional shot pins at marked locations along with anchor bolts per shear schedule. Provide h25 in garage 2 ply girder truss along heel truss in west bedroom at entry. Provide additional nails at shear walls due to shiners. 7/21/2026 |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0925-00506
Permit Description: Mirador Ridge Skies 1708 Plan (TC-MDP-0825-00416)
Total Completed Inspections - 5
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/02/2026 | COT - RSPL - Yard Water Line | Passed | 07/02/2026 Holding under air test. Okay to backfill, shading required. |
|
| 07/02/2026 | COT - RSPL - Sewer | Passed | 07/02/2026 Holding under test to HCS with green tracer wire. Ok to backfill, shading and clean trench required |
|
| 07/02/2026 | COT - RSPL - Rough Soil | Passed | 07/02/2026 Holding under test. Ok to backfill, shading and clean trench required |
|
| 07/02/2026 | COT - RSPL - Backwater Valve | Passed | ||
| 07/21/2026 | COT - RSBU - Roof Nailing | Passed |
Scheduled Inspections
Scheduled Inspections - TC-MDP-0925-00506
Status: Inspections
Description: Mirador Ridge Skies 1708 Plan (TC-MDP-0825-00416)
| Scheduled Date | Description | Entered By | Entered Date |
|---|---|---|---|
| 07/23/2026 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Scheduled |
For information about today’s scheduled inspections please refer to the
PDSD Daily Inspections Dashboards (Desktop)
PDSD Daily Inspections Dashboards (Mobile)
.