Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: TC-MDP-0924-01034
Permit Details
Apply Date:
09/10/2024
Applicant:
Daria Hopkins
Description:
Single Family Residence La Estancia Block E Plan 135.2110
Permit Reviews
Permit Number - TC-MDP-0924-01034
Permit Status: Inspections
Permit Description: Single Family Residence
La Estancia Block E
Plan 135.2110
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
09/23/2024 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 09/30/2024 | APPROVED |
Outstanding Activity Conditions
Permit Number - TC-MDP-0924-01034
Permit Status: Inspections
Permit Description: Single Family Residence
La Estancia Block E
Plan 135.2110
Total Outstanding Activity Conditions - 4
Date | Name |
---|---|
09/18/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/ |
09/25/2024 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
09/25/2024 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. |
09/25/2024 | Post-Tension Inspection Report is required. |
Conditions
Permit Number - TC-MDP-0924-01034
Permit Status: Inspections
Permit Description: Single Family Residence
La Estancia Block E
Plan 135.2110
Date | Description | Comments |
---|---|---|
09/18/2024 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900. | |
09/25/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0924-01034
Permite Description: Single Family Residence
La Estancia Block E
Plan 135.2110
Total Outstanding Inspections - 1
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/10/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | 12/10/24 holes in vapor barrier above kitchen window and by sliding glass door, marked. Inappropriate screws in fan boxes, must use provided hex screws. Pex lines still within 12 inches of lights. Light box with 4 switches must be braced on both sides. STOPPED INSPECTION-ADDITIONAL ITEMS MAY BE NOTED. |
Completed Inspections
Permit Status: Inspections
Permit Number: TC-MDP-0924-01034
Permit Description: Single Family Residence
La Estancia Block E
Plan 135.2110
Total Completed Inspections - 12
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/29/2024 | COT - RSPL - Rough Soil | Passed | 10-29-24, underground plumbing inspection approved.Okay to backfill. | |
10/29/2024 | COT - RSPL - Sewer | Passed | 10-29-24, sewer inspection approved.Okay to backfill. | |
10/29/2024 | COT - RSPL - Yard Water Line | Passed | 10-29-24, main water line inspection approved.Okay to backfill. | |
11/07/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | 11-7-24, setbacks verified as per approved plans. Okay to backfill. | |
11/07/2024 | COT - RSBU - Preslab | Passed | 11-7-24, preslab verified as per approved plans. Okay to pour concrete. | |
11/07/2024 | COT - RSEL - Electrical Underground | Passed | 11-7-24, electrical underground verified as per approved plans. Okay to backfill. | |
11/07/2024 | COT - RSEL - Grounding/Bonding | Passed | 11-7-24, grounding/bonding verified as per approved plans. Okay to backfill. | |
11/20/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | 11-20-24, verified exterior clips/sheathing as per approved plans. Okay to continue with construction. | |
11/20/2024 | COT - RSBU - Roof Nailing | Passed | 11-20-24, verified roof nailing,exterior clips/sheathing as per approved plans. Okay to continue with construction. | |
12/06/2024 | BULD - Electrical Clearance | Passed | 12-6-24, Approved for TEP to energize panel. ECO clearance issued. | |
12/06/2024 | COT - RSPL - Gas Pressure Test | Passed | 12-6-24, gas pressure verified at 15psi. | |
12/12/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | 12/12/24 corrections made |