Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Inspections
Type:
Model Building Permit
Apply Date:
09/10/2024
Applicant:
Daria Hopkins
Description:
Single Family Residence La Estancia Block E Plan 135.2110

Permit Reviews

Permit Number - TC-MDP-0924-01034
Permit Status: Inspections
Permit Description: Single Family Residence La Estancia Block E Plan 135.2110
Start Date Submittal Complete Date Status  
09/23/2024 SITE FROM MODEL PERMIT - PRODUCTION v.1 09/30/2024 APPROVED Review Details

Outstanding Activity Conditions

Permit Number - TC-MDP-0924-01034
Permit Status: Inspections
Permit Description: Single Family Residence La Estancia Block E Plan 135.2110
Total Outstanding Activity Conditions - 4
Date Name
09/18/2024 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/
09/25/2024 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
09/25/2024 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
09/25/2024 Post-Tension Inspection Report is required.

Conditions

Permit Number - TC-MDP-0924-01034
Permit Status: Inspections
Permit Description: Single Family Residence La Estancia Block E Plan 135.2110
Date Description Comments
09/18/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. For review and assessment: apply online at https://permits.pima.gov/ or contact us at sewer@pima.gov, (520) 724-9900.
09/25/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Inspections
Permit Number: TC-MDP-0924-01034
Permite Description: Single Family Residence La Estancia Block E Plan 135.2110
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
12/10/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Re-inspection required 12/10/24 holes in vapor barrier above kitchen window and by sliding glass door, marked. Inappropriate screws in fan boxes, must use provided hex screws. Pex lines still within 12 inches of lights. Light box with 4 switches must be braced on both sides. STOPPED INSPECTION-ADDITIONAL ITEMS MAY BE NOTED.

Completed Inspections

Permit Status: Inspections
Permit Number: TC-MDP-0924-01034
Permit Description: Single Family Residence La Estancia Block E Plan 135.2110
Total Completed Inspections - 12
Date Description Inspector Results Comments
10/29/2024 COT - RSPL - Rough Soil Passed 10-29-24, underground plumbing inspection approved.Okay to backfill.
10/29/2024 COT - RSPL - Sewer Passed 10-29-24, sewer inspection approved.Okay to backfill.
10/29/2024 COT - RSPL - Yard Water Line Passed 10-29-24, main water line inspection approved.Okay to backfill.
11/07/2024 COT - RSBU - Excavation/Rebar/Zoning Passed 11-7-24, setbacks verified as per approved plans. Okay to backfill.
11/07/2024 COT - RSBU - Preslab Passed 11-7-24, preslab verified as per approved plans. Okay to pour concrete.
11/07/2024 COT - RSEL - Electrical Underground Passed 11-7-24, electrical underground verified as per approved plans. Okay to backfill.
11/07/2024 COT - RSEL - Grounding/Bonding Passed 11-7-24, grounding/bonding verified as per approved plans. Okay to backfill.
11/20/2024 COT - RSBU - Exterior Clips/Sheathing Passed 11-20-24, verified exterior clips/sheathing as per approved plans. Okay to continue with construction.
11/20/2024 COT - RSBU - Roof Nailing Passed 11-20-24, verified roof nailing,exterior clips/sheathing as per approved plans. Okay to continue with construction.
12/06/2024 BULD - Electrical Clearance Passed 12-6-24, Approved for TEP to energize panel. ECO clearance issued.
12/06/2024 COT - RSPL - Gas Pressure Test Passed 12-6-24, gas pressure verified at 15psi.
12/12/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 12/12/24 corrections made

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
LOT 84 PLOT PLAN_V1.PDF DOCUMENTS VIEW
LOT 84 SPECIAL INSPECTION CERTIFICATE-2024-09-19_V1.PDF DOCUMENTS VIEW