Permit: TC-MDP-0923-01568
Permit Details
Apply Date:
09/28/2023
Applicant:
Joshua Swinney
Description:
Harding SFR Model La Estancia (roof vent update)
Permit Reviews
Permit Number - TC-MDP-0923-01568
Permit Status: Complete
Permit Description: Harding SFR Model La Estancia (roof vent update)
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
10/02/2023 | SITE FROM MODEL PERMIT - PRODUCTION v.1 | 10/04/2023 | APPROVED |
09/18/2024 | BUILDING DEFERRED SUBMITTAL REVIEW v.1 | 09/18/2024 | APPROVED |
Conditions
Permit Number - TC-MDP-0923-01568
Permit Status: Complete
Permit Description: Harding SFR Model La Estancia (roof vent update)
Date | Description | Comments |
---|---|---|
09/18/2024 | SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED. | |
09/18/2024 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. | |
10/02/2023 | SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED. | |
02/16/2023 | Post-Tension Inspection Report is required. | |
09/18/2024 | Post-Tension Inspection Report is required. | |
08/07/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
09/28/2023 | Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment. | |
08/07/2023 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. | |
09/18/2024 | Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/ | |
09/18/2024 | SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED. | |
02/16/2023 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. | |
09/18/2024 | Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building. |
Outstanding Inspections
Permit Status: Complete
Permit Number: TC-MDP-0923-01568
Permite Description: Harding SFR Model La Estancia (roof vent update)
Total Outstanding Inspections - 8
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/20/2024 | COT - RSPL - Gas Pressure Test | N/A | Not Applicable | |
06/21/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | N/A | Re-inspection required | Secure loose electrical lines at main and ceiling in laundry room. UFER not connected to ground. Fire foam all top penetrations. Nail in ABS pipe at kitchen area. (Refrigerator). Missing receptacles at kitchen island. Seal off all exterior penetrations. Add blocking to all registers. STOPPED INSPECTION. 6/18/2024 6/21/24: per previous notes, refrigerant lines missing, nail plates missing throughout. Not ready |
09/25/2024 | COT - RSEL - Electrical Final | N/A | Re-inspection required | AC breaker above maximum amperage, needs to be changed to a 30 amp, everything else passed |
09/25/2024 | COT - RSEL - Outdoor Lighting | N/A | Re-inspection required | AC breaker above maximum amperage, needs to be changed to a 30 amp, everything else passed |
09/25/2024 | COT - RSME - Mechanical Final | N/A | Re-inspection required | AC breaker above maximum amperage, needs to be changed to a 30 amp, everything else passed |
09/25/2024 | COT - RSPL - Plumbing Final | N/A | Re-inspection required | AC breaker above maximum amperage, needs to be changed to a 30 amp, everything else passed |
09/25/2024 | RSBU - Building Final | N/A | Re-inspection required | AC breaker above maximum amperage, needs to be changed to a 30 amp |
09/25/2024 | RSBU - Building Progress | N/A | Re-inspection required | AC breaker above maximum amperage, needs to be changed to a 30 amp, everything else passed |
Completed Inspections
Permit Status: Complete
Permit Number: TC-MDP-0923-01568
Permit Description: Harding SFR Model La Estancia (roof vent update)
Total Completed Inspections - 20