Permit Details

Status:
Complete
Type:
Model Building Permit
Apply Date:
09/28/2023
Applicant:
Brianna Quiroz
Description:
Harding SFR Model La Estancia (roof vent update)

Permit Reviews

Permit Number - TC-MDP-0923-01568
Permit Status: Complete
Permit Description: Harding SFR Model La Estancia (roof vent update)
Start Date Submittal Complete Date Status  
10/02/2023 SITE FROM MODEL PERMIT - PRODUCTION v.1 10/04/2023 APPROVED Review Details
09/18/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 09/18/2024 APPROVED Review Details

Conditions

Permit Number - TC-MDP-0923-01568
Permit Status: Complete
Permit Description: Harding SFR Model La Estancia (roof vent update)
Date Description Comments
09/18/2024 SPECIAL INSPECTION FOR CONCRETE INSTALLATION IS REQUIRED.
09/18/2024 SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED.
10/02/2023 SPECIAL INSPECTION FOR POST TENSION SLAB IS REQUIRED.
02/16/2023 Post-Tension Inspection Report is required.
09/18/2024 Post-Tension Inspection Report is required.
08/07/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
09/28/2023 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.
08/07/2023 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy.
09/18/2024 Sewer condition must be accepted and released by Pima County prior to issuance of a Temporary Certificate of Occupancy. For More Information visit https://www.pima.gov/1076/Sewer-Connection-Permits, To check your permit status https://permits.pima.gov/
09/18/2024 SPECIAL INSPECTION FOR SPECIAL GRADING, EXCAVATION AND FILLING IS REQUIRED.
02/16/2023 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.
09/18/2024 Truss/Joist Design plans must be submitted and approved prior to intermediate inspections if residential building or finaling the permit if commercial building.

Outstanding Inspections

Permit Status: Complete
Permit Number: TC-MDP-0923-01568
Permite Description: Harding SFR Model La Estancia (roof vent update)
Total Outstanding Inspections - 8
Last Inspection Date Description Inspector Results Comments
03/20/2024 COT - RSPL - Gas Pressure Test N/A Not Applicable
06/21/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. N/A Re-inspection required Secure loose electrical lines at main and ceiling in laundry room. UFER not connected to ground. Fire foam all top penetrations. Nail in ABS pipe at kitchen area. (Refrigerator). Missing receptacles at kitchen island. Seal off all exterior penetrations. Add blocking to all registers. STOPPED INSPECTION. 6/18/2024
6/21/24: per previous notes, refrigerant lines missing, nail plates missing throughout. Not ready
09/25/2024 COT - RSEL - Electrical Final N/A Re-inspection required AC breaker above maximum amperage, needs to be changed to a 30 amp, everything else passed
09/25/2024 COT - RSEL - Outdoor Lighting N/A Re-inspection required AC breaker above maximum amperage, needs to be changed to a 30 amp, everything else passed
09/25/2024 COT - RSME - Mechanical Final N/A Re-inspection required AC breaker above maximum amperage, needs to be changed to a 30 amp, everything else passed
09/25/2024 COT - RSPL - Plumbing Final N/A Re-inspection required AC breaker above maximum amperage, needs to be changed to a 30 amp, everything else passed
09/25/2024 RSBU - Building Final N/A Re-inspection required AC breaker above maximum amperage, needs to be changed to a 30 amp
09/25/2024 RSBU - Building Progress N/A Re-inspection required AC breaker above maximum amperage, needs to be changed to a 30 amp, everything else passed

Completed Inspections

Permit Status: Complete
Permit Number: TC-MDP-0923-01568
Permit Description: Harding SFR Model La Estancia (roof vent update)
Total Completed Inspections - 20
Date Description Inspector Results Comments
03/20/2024 COT - BULD - SWG Clearance Passed
03/28/2024 COT - RSPL - Sewer Passed
03/28/2024 COT - RSPL - Rough Soil Passed
03/28/2024 COT - RSPL - Yard Water Line Passed
04/09/2024 COT - RSBU - Excavation/Rebar/Zoning Passed
04/09/2024 COT - RSBU - Preslab Passed
05/16/2024 COT - RSBU - Exterior Clips/Sheathing Passed
05/16/2024 COT - RSBU - Roof Nailing Passed
07/02/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed Corrections were made. 7/2/2024
07/17/2024 COT - RSBU - Interior Shear Bracing Passed
08/19/2024 BULD - Electrical Clearance Passed Clearance for TEP ECO. 8/19/2024
09/24/2024 ENGR Engineering Final Passed
09/25/2024 COT - RSEL - Electrical Underground Passed
09/25/2024 COT - RSEL - Grounding/Bonding Passed
09/26/2024 COT - RSEL - Electrical Final Passed PASS 9/26/2024
09/26/2024 COT - RSEL - Outdoor Lighting Passed PASS 9/26/2024
09/26/2024 COT - RSME - Mechanical Final Passed PASS 9/26/2024
09/26/2024 COT - RSPL - Plumbing Final Passed PASS 9/26/2024
09/26/2024 RSBU - Building Final Passed PASS 9/26/2024
09/26/2024 RSBU - Building Progress Passed PASS 9/26/2024