Inspection History Details
Inspection Status: Not Ready
Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
Permit Number - TC-MDP-0923-01568
Inspection Description - COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.
Inspection Status - Not Ready
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/18/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Not Ready | Secure loose electrical lines at main and ceiling in laundry room. UFER not connected to ground. Fire foam all top penetrations. Nail in ABS pipe at kitchen area. (Refrigerator). Missing receptacles at kitchen island. Seal off all exterior penetrations. Add blocking to all registers. STOPPED INSPECTION. 6/18/2024 | |
06/21/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | Secure loose electrical lines at main and ceiling in laundry room. UFER not connected to ground. Fire foam all top penetrations. Nail in ABS pipe at kitchen area. (Refrigerator). Missing receptacles at kitchen island. Seal off all exterior penetrations. Add blocking to all registers. STOPPED INSPECTION. 6/18/2024 6/21/24: per previous notes, refrigerant lines missing, nail plates missing throughout. Not ready |
|
06/26/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required | Leak at abs line near refrigerator. Add nail plates to pex lines in garage. 6/26/2024 | |
06/28/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Re-inspection required (with fee) | Provide DWV TEST to verify the abs line has been taking care of. 6/28/2024 | |
07/02/2024 | COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. | Passed | Corrections were made. 7/2/2024 |